26
6.2.2 Calibration Parameters
No.
Range
Default
Description
Set
200
0~130000
10000
[*]
Zero Value
[AD Value]
Zero Value at Idle Speed. Only for query.
201
0.0000
~99.9999
1.0000
[*]
Zero Comp.Coeff.
Zero Compensation Coefficient at Accelerated Speed.
Only for query.
202
1~999999
1000
[*]
Span Coefficient
Span Coefficient at Idle Speed. Only for query.
203
0.0000
~99.9999
1.0000
[*]
Span Comp.Coeff.
Span Compensation Coefficient at Accelerated Speed.
Only for query.
204
5.0~100.0
10.0
[*]
Mag.Block Width
[mm]
Width of Magnet Block fixed on the Nylon Block of the
Position Sensor.
205
0.001~9.999
1.000
[*]
Run Length Ratio
[LR]
Running Length Ratio LR=L1/L3.
L1: The actual running length of Magnet Block passing
by the Lower Proximity Switch [Lower Weighing
Segment].
L3: The actual running length of Magnet Block passing
by the Upper Proximity Switch [Upper Weighing
Segment].
206
0
0
Unused
207
0~1000
500
[*]
Max. Comp.Weight
[kg]
Max. Compensation Weight.
208
-0.0500
~+0.0500
0.0000
[*]
IdleAcc.Value A0
[dm/s
2
]
Acceleration Value at Idle Speed.
Key
【
】
: ‘+’/‘
-
’ switch.
209
0~50
2
Comp. Rate
Weight Compensation Rate.
210
0~99999
100
Comp. Limit
Weight Compensation Limit.