28
6.2.4 Alarm Parameters
No.
Range
Default
Description
Set
400
-1.0000
~0.0000
-0.1000
Stall AlarmPoint
[dm/s
2
]
If ‘Acceleration Value < Stall Alarm Point’, the alarm
message ‘STALL’ will be displayed.
Key
【
】
: ‘+’/‘
-
’ switch.
401
0~99999
5000
Load Lower Limit
[kg]
Lower Limit of Single-bucket-loading-weight.
If ‘Loading Weight < Load Lower Limit’, the alarm
message ‘LOW’ will be displayed.
402
0~99999
30000
Load Upper Limit
[kg]
Upper Limit of Single-bucket-loading-weight.
If ‘Loading Weight > Load Upper Limit’, the alarm
message ‘HIGH’ will be displayed.
403
0.000~99.999
0.100
Min. Weigh Time
[s]
If ‘Weighing Time < Min. Weighing Time’, the alarm
message ‘UND-T’ [undertime] will be displayed..
404
0.000~99.999
30.000
Max. Weigh Time
[s]
If ‘Weighing Time > Max. Weighing Time’, the alarm
message ‘OV-T’ [overtime] will be displayed.
405
0~1
1
Alarm Sound
0: OFF; 1: ON
406
0~1
0
TOT with Alarm
Totalizing Permission While Alarming.
0: OFF; 1: ON
407
0~99999
17000
2-Axle Gross Limit
[kg]
2-Axle Truck Gross Weight Limit.
408
0~99999
25000
3-Axle Gross Limit
[kg]
3-Axle Truck Gross Weight Limit.
409
0~99999
35000
4-Axle Gross Limit
[kg]
4-Axle Truck Gross Weight Limit.
410
0~99999
43000
5-Axle Gross Limit
[kg]
5-Axle Truck Gross Weight Limit.
411
0~99999
49000
6-Axle Gross Limit
[kg]
6-Axle Truck Gross Weight Limit.
412
0~99999
56000
7-Axle Gross Limit
[kg]
7-Axle Truck Gross Weight Limit.
413
0~99999
100000
8-Axle Gross Limit
[kg]
8-Axle Truck Gross Weight Limit.