4
9
KOBE
P R O F E S S I O N A L
AIR TOOLS
TROUBLESHOOTING
Continued
KOBE
P R O F E S S I O N A L
AIR TOOLS
BOX CONTENTS
KOBE
P R O F E S S I O N A L
AIR TOOLS
ELECTRICAL INFORMATION
In the United Kingdom, the
ELECTRICITY AT WORK ACT 1989
requires all portable electrical appliances, if
used on business premises, to be tested by a qualified electrician, using a Portable Appliance Tester (PAT), at
least once a year. The
HEALTH & SAFETY AT WORK ACT 1974
makes owners of electrical appliances
responsible for the safe condition of the appliance and the safety of its operator. If in any doubt about
electrical safety, contact a qualified electrician.
ELECTRICAL SAFETY
An RCCB (Residual Current Circuit Breaker) should be fitted in the mains electricity distribution board. If the
power supply is not protected by an RCCB, it is highly recommended that an RCD (Residual Current Device) is
used with all portable electrical products.
PLUG FITTING
A moulded UK 3 pin plug with ASTA/BS approval is already fitted for your safety.
If it becomes damaged, and needs replacing, cut off the plug and prepare the
wires. Use the following instructions:
a)
Connect the GREEN/YELLOW earth wire to the earth terminal marked either
‘ E’ or with the earth symbol‘ ’.
b)
Connect the BROWN live wire to the live terminal marked ‘ L’.
c)
Connect the BLUE neutral wire to the neutral terminal marked ‘ N’.
d)
After wiring, check there are no bare wires, that all wires have been correctly
connected, that the cable external insulation extends beyond the cable
restraint and that the restraint is tight.
EXTENSION REELS
When a cable extension reel is used it should be fully unwound before being connected. Use at least 1.5mm
2
section cable or to be absolutely sure use 2.5mm
2
section cable.
Yellow & Green = Earth wire
Cable restraint
UK
ONLY
Brown = Live wire
Blue = Neutral wire
KOBE
P R O F E S S I O N A L
AIR TOOLS
SPECIFICATIONS
WORKING PRESSURE (max.)
..........
8Bar/115PSI
PUMP AIR DISPLACEMENT (min.)
.............................
....................................................................................
7.3CFM/210Ltr
AIR RECEIVER TANK CAPACITY
.......................
24Ltr
MOTOR CAPACITY
.......................................................
1.5KW
MOTOR ROTATION SPEED
...........................
2,850rpm
MOTOR SUPPLY VOLTAGE
.......................
230V/50Hz
MOTOR HP
..................................................................................
2HP
ACOUSTIC PRESSURE LWA (max.)
............
97dBa
NET DIMENSIONS
..................
61(H) x 55(W) x 34(D)cm
NET WEIGHT
...........................................................................
25.5kg
QUICK CONNECT COUPLER
.............1/
4
” BSP Female
The room temperature for its correct efficiency is 0
°
C
to +25
°
C (Max 45
°
C).
KOBE
P R O F E S S I O N A L
AIR TOOLS
SERVICE & REPAIR
A comprehensive repair and service
facility is available through your
local agent.
KOBE
P R O F E S S I O N A L
AIR TOOLS
SPARES
For spare parts or servicing please contact your nearest agent. Remember to quote tool model number and
spare part number when ordering spares. The use of other than genuine Kobe replacement parts may
result in safety hazards, decreased tool performance and increased maintenance. When disposing of
components, etc. ensure that relevant environmental procedures are carried out.
Air Intake Filter unit
KBE-298-3900A
Gasket ‘O’ ring
KBE-298-3910K
Drain valve
KBE-298-3911L
Valve set
KBE-298-3901B
x 2
x 2
x 1
x 1
x 4
x 2
x 1
x 1
x 2
x 1
Save the packaging
material for future
transportation of
the compressor in
the event of service
or repair.
Fig. 11
Valve seat
‘O’ ring
POSSIBLE CAUSE
The pre-set pressure
switch is defective or
needs adjusting.
Faulty safety blow off
valve.
SOLUTION
Stop the air compressor immediately and
contact your local Kobe agent.
Contact your local Kobe agent.
FAULT
The motor pump unit does
not stop when the tank
pressure reaches its
maximum working
pressure (116PSI) and the
safety valve vents air.
Safety blow off valve
operates below the
maximum pressure.