background image

2

What to Do In The Event Of a Range Top Grease Fire

• 

SMOTHER FLAMES with a tight fitting lid, cookie sheet, or metal tray, and then turn off the burner.  
KEEP FLAMMABLE OR COMBUSTIBLE MATERIAL AWAY FROM FLAMES.  If the flames do not 
go out immediately, EVACUATE THE AREA AND CALL THE FIRE DEPARTMENT or 911. 

• 

NEVER PICK UP A BURNING PAN – You May Get Burned. 

• 

DO NOT USE WATER, including wet dishcloths or towels – a steam blast will result. 

• 

Use an extinguisher ONLY if: 
a)  You have a Class A, B, C extinguisher and know how to operate it. 
b)  The fire is small and contained in the area where it started. 
c)  The fire department has been called. 
d)  You can fight the fire with your back to an exit. 

What to Do If You Smell Gas

-

Extinguish any open flame. 

-

Do not try to turn on the lights or any type of appliance. 

-

Open all doors and windows to disperse the gas.  If you still smell gas, call the Gas Company and 
Fire Department right away. 

CAUTION

1)  For general ventilation use only.  Do not use to exhaust hazardous or explosive materials and 

vapors.

2)  To reduce the risk of fire, use only metal ductwork.  Sufficient air is needed for proper combustion 

and exhausting of gases through the flue (chimney) to prevent back drafting. 

3)  Follow the heating equipment manufacturer’s guideline and safety standards such as those 

published by the National Fire Protection Association (NFPA), and the American Society for 
Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and code authorities. 

4)  Activating any switch on may cause ignition or an explosion. 
5)  Due to the size and weight of this hood, installation by 2 persons is recommended. 

ELECTRICAL SHOCK HAZARD – Can result in serious injury or death.  
Disconnect appliance from electric power before servicing.  If equipped, 
the fluorescent light bulb contains small amounts of mercury, which 
must be recycled or disposed of according to Local, State, and Federal 
Codes.

Summary of Contents for RA2830SQB-1

Page 1: ...KOBE Brand Range Hood Model No RA3830SQB WM 1 30 RA3836SQB WM 1 36 RA2830SQB 1 30 RA2836SQB 1 36 RA2830SQB WM 1 30 RA2836SQB WM 1 36 INSTALLATION INSTRUCTIONS AND OPERATION MANUAL ...

Page 2: ...n do the installation IF THERE IS ANY PROBLEM 1 DO NOT INSTALL THE UNIT AND KEEP ALL ORIGINAL PACKAGING MATERIAL 2 Have your original invoice as proof of purchase and product serial number ready 3 Call 1 877 BUY KOBE 289 5623 or e mail to info koberangehoods com to report the problem NO RETURN NO REFUND NO EXCHANGE IF 1 PRODUCT HAS BEEN INSTALLED 2 KNOCK OUT HOLES HAVE BEEN PUNCTURED 3 MISSING ORI...

Page 3: ...NANCE 14 SPECIFICATIONS 15 MEASUREMENTS DIAGRAMS 17 PARTS LIST 20 CIRCUIT DIAGRAM 23 TROUBLE SHOOTING 24 WARRANTY 25 PRODUCT REGISTRATION 27 READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING A L L W I R I N G M U S T B E D O N E B Y A P R O F E S S I O N A L A N D I N A C C O R D A N C E W I T H N A T I O N A L A N D L O C A L E L E C T R I C A L C O D E S ...

Page 4: ...eatment negligence or any other circumstances beyond the control of KOBE RANGE HOODS authorized agents Any repair carried out without the supervision of KOBE RANGE HOODS authorized agents will automatically void the warranty KOBE RANGE HOODS will not be held responsible for any damages to personal property or real estate or any bodily injuries whether caused directly or indirectly by the range hoo...

Page 5: ...you still smell gas call the Gas Company and Fire Department right away CAUTION 1 For general ventilation use only Do not use to exhaust hazardous or explosive materials and vapors 2 To reduce the risk of fire use only metal ductwork Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney to prevent back drafting 3 Follow the heating equipment manufacturer s...

Page 6: ...ood B Warranty Registration Card C Instructions Manual CD D Baffle Filter x 2 30 hood x 3 36 hood E 6 Round Plastic Collar F Duct cover Mounting Bracket G Adjustable Duct Cover H Screws Package A B C D Pre installed E Pre installed F G H FOR MORE INFORMATION PLEASE VISIT OUR WEBSITE www KOBERangeHoods com OR CONTACT KOBE RANGE HOODS AT 626 775 8880 3 16 x 3 8 8PCS ...

Page 7: ... 36 Range Hood Box A KOBE Range Hood B Warranty Registration Card C Instructions Manual CD D Baffle Filter x 2 30 hood x 3 36 hood E 6 Round Plastic Collar A B C D Pre installed E Pre installed FOR MORE INFORMATION PLEASE VISIT OUR WEBSITE www KOBERangeHoods com OR CONTACT KOBE RANGE HOODS AT 626 775 8880 ...

Page 8: ...nty Registration Card C Instructions Manual CD D Baffle Filter x 2 30 hood x 3 36 hood E 6 Round Plastic Collar F Duct cover Mounting Bracket G Adjustable Duct Cover H Screws Package A B C D Pre installed E Pre installed F G H FOR MORE INFORMATION PLEASE VISIT OUR WEBSITE www KOBERangeHoods com OR CONTACT KOBE RANGE HOODS AT 626 775 8880 3 16 x 3 8 8PCS ...

Page 9: ...ling B Height of Floor to Counter Top Standard 36 C Preferred Height of Counter Top to Hood Bottom Minimum 26 to 30 D Height of Hood E Height of the Cabinet FOR WALL MOUNT WITH OPTIONAL DUCT COVER TABLE 2 A Height of Floor to Ceiling B Height of Floor to Counter Top Standard 36 C Preferred Height of Counter Top to Hood Bottom Minimum 26 to 30 D Height of Hood E Height of Duct Cover F D F Height of...

Page 10: ... SHARP EDGES PLEASE WEAR PROTECTIVE GLOVES IF REMOVING ANY PARTS FOR INSTALLING CLEANING OR SERVICING NOTE BE CAREFUL WHEN USING ELECTRICAL SCREWDRIVER DAMAGE TO THE HOOD MAY OCCUR Installation Contents UNDER THE CABINET WALL MOUNT 8 10 ...

Page 11: ...rence on Page 18 to measure and create access opening for electrical wires and exhaust under the cabinet Hood Installation CAUTION USE HAND TOOLS ONLY DO NOT OVER TIGHTEN SCREWS IT MAY CAUSE DAMAGE TO THE HOOD CAUTION If moving the cooking range is necessary to install the hood turn off the power in an electric range at the main electrical box SHUT OFF THE GAS BEFORE MOVING A GAS RANGE And use a p...

Page 12: ...AL CODES BEFORE CONNECTING WIRES SWITCH POWER OFF AT SERVICE PANEL AND LOCK SERVICE PANEL TO PREVENT POWER FROM BEING SWITCHED ON ACCIDENTALLY If hood is operating normally connect three wires black white and green to house wires and cap with wire connectors Store wires in the wiring box Install Uninstall Accessories 6 Place baffle filters underneath the hood Figure 7 Final Assembly 7 Turn power O...

Page 13: ...with cross framing lumber for secure installation Using references on Table 2 and measurements on page 17 19 decide the level of the lumber Refer to Figure 9 Hood Installation CAUTION USE HAND TOOLS ONLY DO NOT OVER TIGHTEN SCREWS IT MAY CAUSE DAMAGE TO THE HOOD CAUTION If moving the cooking range is necessary to install the hood turn off the power in an electric range at the main electrical box S...

Page 14: ...the position of the Duct Cover Mounting Bracket F Use reference E from Table 2 and measurements on page 17 19 Attach and secure Duct Cover Mounting Bracket F with two screws not provided Refer to Figure 12 NOTE Inner duct cover will cover the Duct Cover Mounting Bracket 6 Remove the Baffle Filters Position the entire duct cover up onto the hood and secure with six 3 16 x 3 8 screws H from inside t...

Page 15: ...n on prior to any preparation or cooking and keep fans running while cooking Adjust speed as needed To operate the fan function x Press button to choose from speed o Q QuietMode speed o L Low speed o H High speed x Press OFF to turn fan off To operate the light function x Press the Light Control to turn lights on and off ...

Page 16: ...n x Press On Off Control to turn on the power x Once the On Off Control is turned on the prior fan selection will turn on Press the Speed Controls Low High or QuietMode to select the desired speed x QuietMode supersedes all other fan control Turn off QuietMode to use Low or High speed x Press On Off Control to turn fan off To operate the light function x Press the Light Control to turn lights on a...

Page 17: ...born spots Use dry soft towel to dry the hood 3 DO NOT allow deposits to accumulate or remain on the hood 4 DO NOT use ordinary steel wool or steel brushes Small bits of steel may adhere to the surface and cause rusting 5 DO NOT allow salt solutions disinfectants bleaches or cleaning compounds to remain in contact with stainless steel for extended periods Many of these compounds contain chemicals ...

Page 18: ... 038 SQB WM 1 3 Speed Mechanical Push Control For RA 028 SQB 1 and RA 028 SQB WM 1 3 Speed Rocker Switch LIGHTS 3 Watt LED light x 2 HOOD DIMENSION W x D x H RA3830SQB WM 1 29 3 4 x 20 1 2 x 12 5 8 RA3836SQB WM 1 35 3 4 x 20 1 2 x 12 5 8 RA2830SQB 1 and RA2830SQB WM 1 29 3 4 x 19 5 8 x 11 5 8 RA2836SQB 1 and RA2836SQB WM 1 35 3 4 x 19 5 8 x 11 5 8 OPTIONAL ACCESSORIES W x D x H 1 30 Stainless Stee...

Page 19: ...apacity cfm 280 450 680 Sone dB 1 0 2 2 5 0 For 36 Hood RA3836SQB WM 1 RA2836SQB 1 RA2836SQB WM 1 SPEED QuietMode Low High Air Capacity cfm 300 440 750 Sone dB 1 0 2 0 5 6 One sone is equivalent to the sound of a refrigerator at 40 decibels Specifications subject to change without notice ...

Page 20: ...17 MEASUREMENTS DIAGRAMS All inch measurements are converted from millimeters Inch measurements are estimated All measurements in are millimeters MODEL NO RA3830SQB WM 1 30 RA3836SQB WM 1 36 ...

Page 21: ...nts are converted from millimeters Inch measurements are estimated All measurements in are millimeters FOR UNDER THE CABINET MODEL NO RA2830SQB 1 30 RA2836SQB 1 36 FOR WALL MOUNT MODEL NO RA2830SQB WM 1 30 RA2836SQB WM 1 36 ...

Page 22: ...19 Hood Mounting Bracket Duct Cover Mounting Bracke ...

Page 23: ...3 6 Round Plastic Collar L1 0505 0002 4 Hood Mounting Bracket x 2 L1 0201 03900 5 Capacitor RA3830SQB WM 1 L1 0401 0120 04 RA3836SQB WM 1 L1 0401 0120 24 6 LED Light Driver L1 04012 D001 7 Electricial Box L1 0524 0002 8 LED Light 3W L1 0403 0301 9 Control Unit L1 0405 0301 10 Blower System RA3830SQB WM 1 L1 0302 0120 804S RA3836SQB WM 1 L1 0302 0120 802S 11 Baffle Filters L1 0214 0122 ...

Page 24: ...0SQB 1 L1 0401 0120 04 RA2836SQB 1 L1 0401 0120 24 4 LED Light Driver L1 04012 D001 5 Electricial Box L1 0524 0002 6 LED Light 3W L1 0403 0301 7 On Off Switch L1 0405 0101 8 Speed Switch L1 0405 0103 9 Speed Switch QuietMode L1 0405 0104 10 Light Switch L1 0405 0102 11 Blower System RA2830SQB 1 L1 0302 0120 804S RA2836SQB 1 L1 0302 0120 802S 12 Baffle Filters L1 0214 0122 ...

Page 25: ...Bracket x 2 L1 0201 03900 5 Capacitor RA2830SQB WM 1 L1 0401 0120 04 RA2836SQB WM 1 L1 0401 0120 24 6 LED Light Driver L1 04012 D001 7 Electricial Box L1 0524 0002 8 LED Light 3W L1 0403 0301 9 On Off Switch L1 0405 0101 10 Speed Switch L1 0405 0103 11 Speed Switch QuietMode L1 0405 0104 12 Light Switch L1 0405 0102 13 Blower System RA2830SQB WM 1 L1 0302 0120 804S RA2836SQB WM 1 L1 0302 0120 802S...

Page 26: ...23 CIRCUIT DIAGRAM MODEL NO RA3830SQB WM 1 30 RA3836SQB WM 1 36 MODEL NO RA2830SQB 1 30 RA2836SQB 1 36 RA2830SQB WM 1 30 RA2836SQB WM 1 36 ...

Page 27: ... Replace LED light fixture s The light wiring s is loose Check wire continuity from processor board to light transformer to LED light fixture s The control panel or LED light driver is defective Replace the control panel or LED light driver The range hood is not venting out correctly The range hood is installed outside of the manufacture recommended clearance Adjust the clearance between the range...

Page 28: ...defective product and Installation of replacement product ONE YEAR LIMITED WARRANTY FOR PARTS ON KOBE BRILLIA SERIES For one year from the date of your original invoice from a KOBE authorized dealer we will provide free of charge parts to replace those that failed due to manufacturing defects It is our sole discretion to choose to repair or replace defective parts It is your sole responsibility fo...

Page 29: ...avelling and any other expense related to the service request To qualify for warranty service you must 1 Have the ORIGINAL proof of purchase 2 Be the ORIGINAL purchaser of the product 3 Have the model number 4 Have the serial number 5 Have a description of the nature of any defect in the product or part TO REQUEST WARRANTY SERVICE PLEASE CONTACT THE KOBE RANGE HOODS SERVICE CENTER KOBE SERVICE CEN...

Page 30: ...o 3 Serial No For warranty service or spare parts purchase contact KOBE Service Center Toll Free 1 855 800 KOBE 5623 Email kobe adcoservice com To report a problem please contact Toll Free 1 877 BUY KOBE 289 5623 Email customer service koberangehoods com For product information contact Toll free 1 877 BUY KOBE 289 5623 Email info koberangehoods com Your notes ...

Page 31: ...dé d utiliser cette hotte à l étranger puisque l alimentation électrique pourrait ne pas être compatible et enfreindre le code de l électricité de ce pays L usage de la hotte KOBE à l étranger est à votre propre risque et la garantie sera annulée Esta campana de extracción KOBE ha sido fabricada para ser utilizada únicamente en EE UU y CANADÁ No recomendamos la utilización de esta campana en el ex...

Reviews: