This will make both high and low pressure
extreme and exert a bad influence on the
pressure switch operation and the air
conditioning system.
-Figure (C) :
Shows that the refrigerant is insufficient.
Have the refrigerant recharged at your
KOBELCO distributor.
4
-Keep the air conditioner ready for use all year round.
Operate the air conditioner at least once every week for several minutes to rotate the compressor
regardless of the season. This will prevent the refrigerant gas from leaking from the compressor
sealing.
-When oil comes out from the pipe joint, contact our dealer/distributor because it is a sign of gas
leaking.
-Follow the following regulations to conserve global environment.
1. Do not release refrigerant which is sealed in this unit in to atmosphere.
2. Extract the sealed refrigerant from unit when disposing this unit.
[