1.
Make sure that the buzzer stops sounding.
2.
Set the accel potentiometer to low idling
position.
3.
Return the starter key switch to "ACC" or
"OFF" once and restart the engine.
8.2 Auto Idling Stop Function
This switch is usually set to "OFF". When the auto idling stop function is selected, the engine stops
automatically after an elapse of the specified time with the safety lock lever (1) set to "LOCKED"
position (A) during engine operation. This function is effective in saving of fuel and in restraint of
exhaust gas by setting auto idling stop function.
1. After setting safety lock lever to "LOCKED" position (A), the engine changes to "DECEL" speed
about 4 seconds later.
2. Buzzer sounds for 5 seconds before engine stops.
Restart the engine after the engine is stopped by
When carrying out the work there is a possibility of dropping the load due to stop of engine, make
sure to turn the auto idling stop switch OFF.
-When you start the engine again after an auto idling stop, start after once returning a key switch at
ACC or OFF and also returning a throttle potentiometer to Lo.
But the engine cannot starts until a buzzer stops, after engine stops.
-When you leave from machine for a while, turn off the starter key switch to prevent from accident.
-Turn the auto idling stop switch off when the following functions are employed. The engine stops and
then the function stops, too.
As the safety lock lever is set to "LOCKED" position (A),
a. When desired to warm up the engine,
b. When desired to use air-con,
c. When desired to use work light continuously,
-The auto idling stop switch does not function regardless of the auto idling stop switch set position in
the following cases.
a. When the alarm for "HIGH ENG WATER TEMP" or "LOW ENGINE WATER LEVEL" is displayed,
b. When the auto warming up is operated,
[
2. MACHINE FAMILIARIZATION
]
2-14
Copyright © 2015 Kobelco Construction Machinery Co.,Ltd. All rights reserved. [S2YF00022ZE01] [0731CsCshWbYs]