 USER MANUAL CENTRAL HEATING STATION TYPE C32SPV24MEC; C32SPV31MEC

 

 

REV.12.06.2017

 

 

 

      

9 of 18

 

 

 

Caution! Obligatory operation! 
Check the correct functioning of the pump with no fuel in the central heating station.  
Defficient thermal transfer can cause the melting of the vent pipe of the ventilator, errors of the central heating station 

damage of the main switch of the station.  
Incorrect airing of the installation can cause damage of the main heating switch. 

 
 
Note!  
Recommended pressure on the thermal circuit is 1.5 bars. 

                                                 

Emptying the central heating station

  

Emptying of the station implies the following: 
- turn off the station by pressing Power si switch off the electric power, close the gas tap; 
- close the thermal tap and the cold water input tap; 
- open the filling tap (fig.1.4), and then the consumer point of hot house water. 
 

Caution! 
Danger of hot water burns when emptying the station. 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for C32SPV24MEC

Page 1: ...C C32SPV31MEC Image for presentation only Product may look slightly different depending on the area and the purchase period KÖBER SRL no 25 Vaduri Alexandru cel Bun Commune Neamt 617511 Romania Tel 40 233 24 17 46 233 24 19 33 Fax 40 233 24 19 29 www motan ro ...

Page 2: ... 2 3 Graphic context Stand by 10 9 2 4 Graphic context error state 11 9 2 5 Graphic context waiting state 11 9 2 6 Graphic context functioning state 11 9 2 7 Graphic context adjustment of functioning parameters 11 9 2 8 Graphic context Service submenu 12 9 3 Central heating station startup 12 9 4 Functioning as waste hot water station WHW 12 9 5 Functioning as heating station HS 12 9 6 Preset func...

Page 3: ...le with limited psychological and sensitive capacities including children or by people with no experience or and no knowledge The station provides both heating in closed circuit central heating installations as well as hot water Use for other purposes or for additional purposes other than stipulated is considered inappropriate use The manufacturer is not responsible for possible damage resulting f...

Page 4: ...ure min max on thermal circuit 0 5 3 5 bar Maximum pressure on DHW circuit 8 bar Temperature on thermal circuit 30 80 C Temperature on the floor heating system circuit 15 45 C Temperature on domestic hot water circuit 35 55 C Hot water flow t 30 C 10 l min 12 l min Electric characteristics Input 230VAC 50 Hz Rated power EEI pump 0 2 70 W Construction characteristics Height 700 mm Width 436 mm Dept...

Page 5: ... 60 humidity between 20 30 C in order to prevent the damaging of electronic components Caution The burning air of the station must not contain substances such as flourine vapours chlorine sulphur dissolvants colorants adhesives or gasoline These substances can lead in time to the corrosion of the equipment and air gas incoming outgoing pipes Legend A Thermal input connector B Hot water output conn...

Page 6: ...n of the central heating station in the proximity of a swimming pool washing machine or cleaner can result in the contamination of the burning air with these compounds Water pH must be within the following limits 7 5 pH 9 5 It is recommended to check the water and thermal agent pH frequently and if the value does not fall within the limits provided by the manufacturer it will be treated again Wate...

Page 7: ...return of the thermal circuit installation When installing connecting pipes it is essential for these not to be tensed to avoid creating areas of leakage Maximum working pressure allowed is 3bar Recommended working pressure is 1 5 bar Caution It is forbidden to use the central heating station without thermal agent or partilally filled danger of explosion It is forbidden to use the central heating ...

Page 8: ... Electric powering of the central heating station will be executed from a separate circuit provided with differential protection fuses of 30 mA External connections must comply with applicable norms Connection to the electric grid of the building must allow the entire electric insulataion of the central heating station for situations when interventions are required Grid connection is done taking i...

Page 9: ...of the main switch of the station Incorrect airing of the installation can cause damage of the main heating switch Note Recommended pressure on the thermal circuit is 1 5 bars Emptying the central heating station Emptying of the station implies the following turn off the station by pressing Power si switch off the electric power close the gas tap close the thermal tap and the cold water input tap ...

Page 10: ...er in the installation submenu Used to decrease the set temperature on hot water circuit or the value parameter in the installation submenu Used to switch the station on off Used to reset the electronic control board from an error state Used to change the functioning mode winter summer Used to activate deactivate the light on the display Description of graphic symbols in the LCD display Descriptio...

Page 11: ...on is 1 4 bar working mode is summer and the temperature in the installation is 17 C 9 2 6 Graphic context functioning state This state is associated with the presence of flame or the functioning of the circulation pump of the station In this state all the activating state elements of the central heating station are active and the burning request is accepted The display shows the delivered instant...

Page 12: ...est has priority over the heating request in the winter mode The station can function as instant WHW or as accumulation boiler WHW the boiler is functioning of the station as an accumulation boiler WHW station please contact an authorised service company In intant regime the minimum flow of hot water detected by the station is 2 4 l min For confort in using the station as a WHW station we recommen...

Page 13: ...e detection Manually resettable by pressing RESET E25 YES BCU malfunction Manually resettable by pressing RESET E30 YES Malfunctioning burnt gases sensor Manually resettable by pressing RESET E31 NO Malfunctioning thermal input sensor Manually resettable by pressing RESET when the cause disappears E32 NO Malfunctioning thermal output sensor Manually resettable by pressing RESET when the cause disa...

Page 14: ...ed table 2 by which the user signs that they are aware of the correct way of using the central heating station This statement is also signed by the authorized person who commissioned the central heating station The authorised person who commissions the station has the right to refuse to sign the station commissioning statement if they notice defects of the local connecting installations and will n...

Page 15: ...ON TYPE C32SPV24MEC C32SPV31MEC REV 12 06 2017 15 of 18 11 Drawings necessary for mounting and installation 11 1 Types of configurations for mounting the flue kit 1 m max Min 3 2 Min 1 5 m min min1m 1 m max Min 3 2 Min 1 5 m min min1m ...

Page 16: ... Pump error codes If the pump has detecte one or more errors the bi colour LED 1 changes from green to red When an error is active LEDs indicate the type of error as presented in table 7 If more alarms are active at the same time LEDs show the rror with the highest priority Tab 7 Pump error codes 11 3 Hydraulic characteristic of non ER P pump Q PUMP FLOW mc h Display Meaning Pump action Repair 1 L...

Page 17: ...4MEC C32SPV31MEC REV 12 06 2017 17 of 18 11 4 Functioning schemes covered by warranty 11 4 1 Central heating with radiators and instant preparation of domestic hot water 11 4 2 Underfloor central heating and instant preparation of domestic hot water ...

Page 18: ...EC C32SPV31MEC REV 12 06 2017 18 of 18 11 4 3 Central heating with radiators and accumulated preparation of domestic hot water accummulation boiler 11 4 4 Underfloor central heating and accumulated preparation of domestic hot water accummulation boiler ...