USER MANUAL CENTRAL HEATING BOILER TYPE C38GC25; C38GC25-P; C38GC29; C38GC35; C38GC35-CH1; C38GC35-CH2
REV. 01.07.2019
13 din 37
4.2
Dimensions and mounting positions
4.2.1
Installation site
When choosing the installation site, please take into
consideration the following safety instructions:
Caution!
Do not install the BOILER in spaces that are
exposed to freezing! In case of freezing
the sation can be damaged.
This equipment can not be installed and used in
open air. Outdoor installation can cause functioning
flaws.
Caution!
It is not recommended to install the central heating
BOILER in bathrooms or kitchens or other areas with
high humidity.
The BOILER can be installed only in rooms with
maximum 60% humidity between 20-30°C in order
to prevent the damaging of electronic components.
Caution!
The burning air of the BOILER must not
contain substances such as flourine
vapours, chlorine, sulphur, dissolvants, colorants,
adhesives or gasoline. These substances can lead in
time to the corrosion of the equipment and air/ gas
incoming/ outgoing pipes.
Legend:
A – Thermal input connector
B – Hot water output connector
C - Fuel input connector
D - Cold water input connector
E - Thermal output connector
Fig. 1.2 Dimensions and mounting positions for models
C38GC25, C38GC29, C38GC35, C38GC25-P:
Type
Model
Dimensions (mm)
a
b
c
d
e
C38GC25
MKDENS25
203
212
116
152
330
C38GC29
MKDENS29
211
204
180
220
386
C38GC35
MKDENS35
211
204
180
220
386
C38GC25-P
MKDENS25-P
203
212
130
192
330
Fig. 1.2