USER MANUAL CENTRAL HEATING BOILER TYPE C38GC25; C38GC25-P; C38GC29; C38GC35; C38GC35-CH1; C38GC35-CH2
REV. 01.07.2019
26 din 37
After the BOILER is switched off in safety conditions, the user will contact the authorized service company in the area.
7.4
User training
It is obligatory for the specialized personnel commissioning the BOILER to instruct the user about the following aspects:
1.
Central heating BOILER switch on/ off procedure in safety conditions by checking the following elements:
- electrical power connection;
- fuel (gas) connection;
- feeding and filling the thermal circuit;
- the BOILER filling tap must be turned off;
- the pressure in the installation by reading the control panel (
1.5bar
);
- the BOILER taps on the house water circuit must be turned on.
2.
The functioning way of the BOILER and possible problems that may occur. Also each key and symbol on the control panel
must be explained.
3.
Warn the user that a drop in the water pressure of the system is caused by loss of thermal agent which needs to be
mended before using the BOILER again.
4.
Warn the user on the works performed on the air/ gases input/ output systems. Warn the user that
changing them is strictly
forbidden.
5.
It is recommended that the user should have the BOILER verified by an authorized person at least once a year.
6.
Warn the user about the the precautions that need to be taken against freezing.
7.
Hand the user the user manual of the central heating BOILER.
At the end of training a commissioning statement is signed (table 2), by which the user signs that they are aware of the correct
way of using the central heating BOILER. .
This statement is also signed by the authorized person who commissioned the central heating BOILER.
The authorised person who commissions the BOILER has the right to refuse to sign the BOILER commissioning statement if they
notice defects of the local connecting installations and will not sign the commissioning statement until these defects have been
remedied.
7.5
Quality Conditions and Warranty
The company KÖBER S.R.L. - VADURI BRANCH as the manufacturer, guarantees the correct functioning of the central heating
BOILER if are observed ALL conditions for the installation, commissioning, use and periodical technical revision established in the
“Warranty Certificate” given by the manufacturer and signed by the authorized company in the presence of the beneficiary
when the product is purchased.
The Warranty Certificate that comes with the product details all the limits of the warranty. Please carefully follow the directions in
the Warranty Certificate and before reporting any malfunctioning of the BOILER make sure that all the local connecting
installations are of the required quality!
Caution!
Not observing the conditions of the warranty certificate results in losing warranty.
8
INSPECTION AND MAINTENANCE
8.1
Inspection and maintenance intervals
It is obligatory to perform the periodical technical inspection in accordance to applicable law.
In the warranty period of the BOILER the periodical technical inspection will be performed by companies authorised by KÖBER
S.R.L. - VADURI BRANCH.
In order to ensure permanent availability, safety in functioning, efficiency and extended working life, it is recommended that a
yearly technical inspection should be performed by the authorized agreed company. This is why we recommend that you sign
a service and maintenance agreement.
It is recommended that this inspection should be performed before the cold season when the BOILER is used at full capacity.
Danger!
Inspections, maintenabce and repair work are allowed only to technicians authorised and agreed by KÖBER S.R.L. -
VADURI BRANCH.
Not having inspections/ maintenance work can result in material and physical damage.
In order to benefit from all the BOILER function for an extended period of time we recommend the use of original
spare parts.