MEMORY CARD (optional)
Parameters and setpoint values can be copied from one device to
another using the Memory card
There are two methods:
Insert the memory card when the controller is off.
On activation display 1 shows
and display 2 shows
.
(Only if the values stored on Memory Card are correct).
By pressing the
key display 2 shows
.
Confirm using the
key .
The device loads the new data and starts again
.
With the controller disconnected from the power supply:
The memory
card is equipped with an internal battery with a life of about 1000
uses.Insert
the memory card and press the programming button.
When writing the parameters, the LED turns red and on completing the procedure
it changes to green. It is possible to repeat the procedure.
To
the memory card values, follow the procedure described in the first
method, setting display 2 to
so as not to load the parameters on controller.
Enter configuration and change at least one parameter.
Exit configuration. Changes are saved automatically.
With the device connected to the power supply:
update
. Attention: Pls. perform first an update of the
memory card.
UPDATING MEMORY CARD.
SIZE AND INSTALLATION
INTRODUCTION
Thanks for choosing a KOBOLD device.The DAG-Z2 can be set in 2 different
modes: Single or Double counter, all with independent settings. 3 universal
digital inputs are available (NPN/PNP/Potential free contact) and can be used
for bidirectional encoders reading, UP/DOWN counter function, LOCK/HOLD to
lock or hold current visualization.One input is also analogue in order to allow
setpoint modification by an external
WIRING DIAGRAM
To modify Set1 or Set2 by external potentiometer follow the steps below:
-use potentiometers 0 to 5/10kohm
-connect cursor to pin I3; a wrong connection may damage the potentiometer and
lead to lock of the device.
accuracy on input is max 1000 points, therefore set the parameters
"Upper limit"
and "Lower limit" with a max difference of 1000 units.
(Ex.: LoS1 to 50,0 and uPS1 to 150,0 to modify preset
value related to Set1
between 50 and 150 pulsess with steps of one tenth). Greater differences would
make unstable the less signi
fi
cant digit.
-To calibrate the scale of potentiometer enter the con
fi
guration mode and select:
as Pot
as
or
as Enable
Exit con
fi
guration mode and place potentiometer at minimum level and press
key,
then place potentiometer at max level and press premere
key: the device
automatically exit the calibration procedure.
N.B.: A switch-off of the device would interrupt the calibration.
1
2
3-
4
Hin.3
Fin.3
Set1
Set2
P.tAr
Visualizes SETPOINT 1 / 2
or
Modify selected SET
Selects chosen digit
1
2
2a
Modify blinking digit of selected SET
3a
or
PRESS
DISPLAY
SETPOINT MODIFICATION
POTENZIOMETRO 5..10 Kohm
Risoluzione 1000 punti
GND
POSITIVO
Fase
Z
Encoder
Fase
B
Fase
A
PNP
NPN
PRESS
for 3 seconds
Display 1 shows
and 1st digit
fl
ashes.
Display 2 shows
DISPLAY
FUNCTION
or
Modify
fl
ashing digit and
pass to the next one pressing
Enter password
to con
fi
rm
Device loads
default settings
Switch-off and restart
the device
1
2
3
LOADING DEFAULT VALUE
Proximity
Sensor PNP
3 wires
Proximity
Sensor PNP
2 wires
+
-
OUT
OUT
Read carefully the safety guidelines and programming instructions contained in
this manual before using/connecting the device.Disconnect power supply
before proceeding to hardware settings or electrical wirings.Only quali
fi
ed
personnel should be allowed to use the device and/or service it and in
accordance to technical data and environmental conditions listed in this
manual.Do not dispose electric tools together with household waste materials
in observance of European Directive 2002/96/CE.
1
2
3
28.5 x 70.5 mm
Frontal panel cut-out
2
mm
Suggested thickness
÷8
77 mm
35 mm
53 mm
7
CN1
1
6
Memory Card (optional)
with battery
Order-no. SFUR0KIT
Gasket for 32x74
TECHNICAL DATA
Operating conditions
Sealing
Material
Digital Inputs
Outputs
OUT 24V
Back-UP
Power Supply
Operating temperature 0-40°C, humidity 35..95uR%
PC ABS UL94V0 self-extinguishing
3 x I3 PNP/NPN configurable as analogue for potentiometers.
2 relays 5A resistive charge
Rechargeable battery, approx. 7days autonomy
24 to 230VAC/VDC +/-15% 50/60Hz / 2W
Front panel IP65 (with optional gasket) ,
Box IP30, Terminal blocks IP20
(max 28 VDC in PNP mode)
30mA(at 24 VAC supply),
40 mA(at 24 VDC supply),
60 mA (at 110 to 230 VAC)
LOADING DEFAULT VALUES
This procedure restores the factory settings of the instrument.
Potentiometer
Report the activation of Q1
MEANING
Report the activation of Q2
LED
2
1
1
1
1
2
Report serial transmission by the
DAG-Z2
1
1
2