background image

DAG-Z2F80W2 

K0

2

/

0

4

14

 

Declaration of Conformance 

We,  KOBOLD  Messring  GmbH,  Hofheim-Ts,  Germany,  declare  under  our  sole 
responsibility that the product: 

Counter/Preset Counter: DAG-Z2F80W2 

to which this declaration relates is in conformity with the standards noted below: 

EN61000-6-3 
EN61000-6-4 
EMV emission 

EN61000-6-2 
EN61000-4-2 
EN61000-4-3 
EN61000-4-4 
EN61000-4-5 
EN61000-4-6 
EN61000-4-8 
EN61000-4-11 
EMV immunity 

EN61010-1 
Safety Extra Low Voltage 

Also the following EWG guidelines are fulfilled: 

2006/95/EC 

Low Voltage Directive 

2004/108/EC 

EMC Directive 

Hofheim, 

17

Feb

. 20

14

 

H. Peters 

M. Wenzel 

General Manager 

Proxy Holder 

Summary of Contents for DAG-Z2F80W2

Page 1: ...Operating Instructions for Counter Preset Counter Model DAG Z2F80W2 ...

Page 2: ...er enter the configuration mode and select as Pot as or as Enable Exit configuration mode and place potentiometer at minimum level and press key then place potentiometer at max level and press premere key the device automatically exit the calibration procedure N B Aswitch off of the device would interrupt the calibration 1 2 3 4 Hin 3 Fin 3 Set1 Set2 P tAr Visualizes SETPOINT 1 2 or Modify selecte...

Page 3: ...minimum value 0 to 9999 P 39 Lower Limit Set 2 Set 2 minimum value 0 to 9999 Default 0 Default 0 P 22 Upper Limit Set 1 Set 1 maximum value 0 to 9999 Default 999 Default 999 P 23 Automatic Load Counter 1 Counter 1 automatic loading P 40 Upper Limit Set 2 Set 2 maximum value 0 to 9999 AUTOMATIC LOAD CONFIGURATION COUNTER LOAD VALUE CONFIGURATION P 24 Counter Load Value 1 Counter 1 loading value P 4...

Page 4: ... I1 I2 Load I1 I2 Load I1 I2 Load I1 I2 Load I1 I2 Load Counts Load Counts Load Counts Load Counts Load Counts Load Counts Load Counts Load Counts Load Counts Load Counts Load OUTPUT CONFIGURATION Q1 P 31 Output Q1 Setup Disable Out Counter 1 n o Out Counter 1 n c Out Counter 2 n o Out Counter 2 n c Q2 P 32 Output Q2 Setup Disable Out Counter 1 n o Out Counter 1 n c Out Counter 2 n o Out Counter 2...

Page 5: ...elates is in conformity with the standards noted below EN61000 6 3 EN61000 6 4 EMV emission EN61000 6 2 EN61000 4 2 EN61000 4 3 EN61000 4 4 EN61000 4 5 EN61000 4 6 EN61000 4 8 EN61000 4 11 EMV immunity EN61010 1 Safety Extra Low Voltage Also the following EWG guidelines are fulfilled 2006 95 EC Low Voltage Directive 2004 108 EC EMC Directive Hofheim 17 Feb 2014 H Peters M Wenzel General Manager Pr...

Reviews: