background image

  

NBK-M 

11. Order Codes 

Model 

Nominal Pressure 

Connection 

Nominal Diameter 

Roller Indicator 

Transmitter 

Medium Density 

Optionsn 

NBK-M 

1= PN 6  
    (not for ASME-Fl.) 

F= DIN Flange 

10= DN 10  
      (only fori DIN Fl.) 

0= without 

0= without 

8= from 0.8 g/cm³  0= without 

 

2= PN 16 (150 lbs) 

A= ASME-Flange  15= DN 15, 1/2" 

P= PP-rollers 

T= magnetostrictive 

1= from 1.0 g/cm³  ...= (see list) 

 

3= PN 40 (300 lbs) 

R= R-Thread 

20= DN 20, 3/4" 

K= ceramic rollers  W= resistive 

 

  N= NPT-Thread 

25= DN 25, 1" 

M= resistive  with 
transmitter 

 

NBK-R 

Standard limit contact 

 

 

NBK-Rex 

Limit contact-Eex d IIC T6 

 

 

NBK-RT200 

High-temperature contact max. 200 °C 

 

 

 

 
 
 

12. Maintenance 

The drain plug should be opened now and again, to wash out any deposits in 
case the liquid to be measured contains dirt particles, which could settle in the 
bypass tube. If coatings have formed, the tank must be emptied or shut off; the 
lower cover flange must then be removed. The float should then be removed 
carefully from the vessel. The bypass tube can now be mechanically cleaned. 
 
The inspection window for the roller indication is made of high-quality plexiglass 
(glass for high-temperature display). It should be cleaned with a suitable cleaning 
agent. 
The indicator requires no further maintenance. 
 
 

NBK-M_manual_3-5-04.doc  

Page 

13 

Summary of Contents for nbk-m

Page 1: ...Operating Instruction Mini Bypass Level Indicator Model NBK M NBK M_manual_3 4 04...

Page 2: ...10 Technical Information 11 11 Order Codes 13 12 Maintenance 13 13 Dimensions 14 Manufactured and sold by Kobold Messring GmbH Nordring 22 24 D 65719 Hofheim Tel 49 0 6192 2990 Fax 49 0 6192 23398 E M...

Page 3: ...ages during transit What s included in the shipment The standard delivery includes Level Indicator model NBK M Operating Instructions Note If switches were ordered as an option they will not be attach...

Page 4: ...e chemically resistant to the liquid being measured Proper operation is also impaired by High degree of soiling Solids Crystallization Ferrite particles 4 2 Adjustable setpoint switches option The opt...

Page 5: ...ll therefore will correspond to the level in the vessel to which it is attached A float with flush encased magnet in the bypass tube follows the liquid level The magnetic float activates a roller indi...

Page 6: ...gnetic roller indicator if not already mounted on the bypass tube with the two accompanying clamps Mount and tighten the Switches if supplied on the bypass tube with the accompanying clamps The roller...

Page 7: ...rical supply lines are de energized To avoid faults caused by electrical fields from other circuits the cable should not be laid in conduits with power cables cables Unscrew cover and pull supply line...

Page 8: ...smitter and the magnetostrictive transducers are not suitable for installation in hazardous locations CAUTION Installers must be familiar with all local and national codes concerning electrical device...

Page 9: ...Us AGND AOUT 4 20 mA 24 V DC 8 Startup Fill vessel and switch on the electrical controller if present The entering liquid lifts up the float and thus the coupled magnet actuator The roller indicator...

Page 10: ...float movement is achieved by factory tuning of the float magnet and the contact 9 Trouble Shooting Error The tank is full but there is no indication Check that the float is present in the system If t...

Page 11: ...hing capacity 60 W VA 230 VAC DC 1 0 A NBK R Process temperature max 100 C 212 F Ambient temperature max 75 C 170 Protection type IP 67 NEMA 4X Connection 3 Ft PVC cable Case plastic Limit contacts mo...

Page 12: ...Resolution 10 mm 0 4 for measuring length 78 20 mm 0 8 for measuring length 78 Transmitter model T Magnetostrictive sensor with 4 wire transmitter Output 4 20 mA Load max 500 Max length 4000 mm 160 Su...

Page 13: ...ontact Eex d IIC T6 NBK RT200 High temperature contact max 200 C 12 Maintenance The drain plug should be opened now and again to wash out any deposits in case the liquid to be measured contains dirt p...

Page 14: ...M 13 Dimensions NBK M with roller indication millimeters Dimension C mm for DIN V Flange Model DN 10 DN 15 DN 20 DN 25 PN 6 46 47 47 46 PN 16 53 52 53 49 PN 40 53 55 55 51 Page 14 NBK M_manual_3 5 04...

Page 15: ...ctive transmitter millimeters Dimension C mm for ASME V Flange Model 1 150 lbs 46 47 47 300 lbs 53 52 53 Dimension C for R or NPT thread 60 mm Dimension A Medium density 0 8 g cm 285 mm Medium density...

Page 16: ...ess steel 1 4571 L1 Drain valve G 1 4 stainless steel 1 4571 L2 Drain valve 1 4 NPT stainless steel 1 4571 H1 Rinsing connection DN 15 PN 16 top and bottom H2 Rinsing connection ASME 1 2 150 lbs top a...

Reviews: