User’s Manual
11–4
5B9615
The Processor Status field indicates the current condition of the Processor. These
conditions are “Processor Ready,” “Processor Not Ready,” “Film in Processor,” or
“Processor Off-line.”
The error description field provides an error number of any error that may occur in the
Processor, such as, “Processor Error: E134.” When errors are initially reported, the Error
Recovery Screen displays the error text. After returning to this screen, just the numeric
code will appear as illustrated above. If this error is a Processor error that the user
chooses to override, this line will be displayed in flashing mode. If there is not an error,
this line will be blank. There are 3 errors that you can override. They are “E132
Developer under temperature,” “E133 Developer over temperature,” and “E134 Dryer
under set temperature.”
CONTROL PROCESSOR
F1
F2
F3
Select the desired function.
Increase Dry Set
Decrease Dry Set
Setup Processor
Return
F6
Processor Ready
Processor Error: Exxx
Dev:
Fix:
Dry:
temp=100.0F
temp=100.0F
temp=119.5F
Set=100.0F
Set=100.0F
Set=120.0F
F6
F5
F4
F3
F2
F1
F4
Override Error
H126_9048GC
H126_9048GCA
error description field
Processor status field
commands
prompt lines
Summary of Contents for Ektascan 2180
Page 70: ...User s Manual 3 44 5B9615 ...
Page 100: ...User s Manual 4 30 5B9615 ...
Page 116: ...User s Manual 5 16 5B9615 ...
Page 162: ...User s Manual 8 20 5B9615 ...
Page 164: ...User s Manual 9 2 5B9615 ...
Page 178: ...User s Manual 12 2 5B9615 ...
Page 202: ...User s Manual 14 6 5B9615 ...
Page 226: ...User s Manual 16 12 5B9615 ...
Page 258: ...User s Manual 18 20 5B9615 ...