Figure 15–1
Removal of the Developer Filter
[15] Change the Developer Filter each month. Follow these steps to change the
Developer Filter.
(a) Check that all electrical power to the Processor is OFF.
(b) Lift the Top Cover of the Processor.
(c) Remove the Wet Section Cover, and the Replenisher Hose from the Mandrel
Assembly as illustrated.
Note
When removing the Mandrel Assembly, place a Drip Tray under it to prevent
contamination of the fixer.
(d) Rotate the Mandrel Assembly so that the notch in the top of the Mandrel
Assembly is aligned with the clip on the Level Sensor Housing.
H127_0135GA
hose
replenisher
filter
developer
mandrel
H127_0135GCA