7-14
A-61670 August 2014
Replacing the imaging
guides
The imaging guides should be replaced when they are heavily scratched and
defects show in the image.
NOTE: Handle the imaging guides carefully so as to not put fingerprints on the
guides.
1. Open the scanner cover.
2. Using the screwdriver provided with the scanner, loosen the screws on
each end of the lower imaging guide and remove it from its position.
3. Install the new imaging guide and tighten the screws to secure the imaging
guide.
4. Repeat Steps 2 and 3 to replace the upper imaging guide.
5. Close the scanner cover.