If an emergency shutdown is necessary, first try to use an
emergency stop button.
●
If an emergency stop button is not accessible, turn the power switch
counterclockwise to the off position.
Emergency stop buttons
Emergency stop buttons stop laser operation and mechanical
movement.
Each emergency stop button is a red button on a yellow background.
Depending on the device and the emergency stop button's location on
the device, it may look like one of the following images:
Figure 27: Emergency stop button
An emergency stop button does not disconnect power to the imager or
platesetter. Therefore, you can continue to check the device control
software for information about how to solve a problem.
If you press an emergency stop button, you must reset it before the
platesetter or imager can return to normal operation. To reset the
button, rotate it clockwise until it pops up, click the
Resume
operation
in the device control software, and follow the instructions in the
recovery messages.
Emergency stop buttons are located in the following areas:
●
On the exterior of the platesetter, to the right of the load table
●
Several locations inside the platesetter, under the rear hood and
behind the rear panel
An emergency stop button is located at the front right side of the load
table on a Kodak Magnus VLF Semiautomatic platesetter or the Flexcel
NX Wide imager.
Emergency stop buttons
25
Summary of Contents for Magnus VLF Q2400
Page 2: ......
Page 4: ......
Page 6: ...vi Magnus VLF Q2400 Q3600 Platesetter Safety Guide for Operators ...
Page 14: ...8 Chapter 1 Introduction to safety information ...
Page 22: ...16 Chapter 2 Safe operation ...
Page 26: ...20 Chapter 3 Safe maintenance ...
Page 45: ...Figure 49 High touch current label Electrical hazards 39 ...
Page 46: ...40 Chapter 5 Hazards ...
Page 47: ......