●
On the exterior of the platesetter, to the left and right of the load
table (two emergency stop buttons)
●
Several locations inside the platesetter, under the rear hood and
behind the rear panel
●
On the APL
WARNING: Assume that laser and mechanical hazards may still be present for a
few moments after you press an emergency stop button, and remember that the
electrical power is still connected. When the emergency stop mechanism is
activated, it can take up to two seconds to completely shut down the laser sources
and up to 15 seconds for the system to shut down mechanical movement.
Exposure to visible and invisible high-powered laser radiation can burn skin and
can cause permanent degradation or loss of eyesight. Moving mechanical parts
can create a hazardous situation, which, if not avoided, can result in death or
serious injury.
APL safety features
The optional APL component has a set of unique safety features
besides the extra emergency stop buttons. These include a cable-
activated emergency stop device, two exit hatches, and internal lights.
Cable-activated emergency stop device
The APL component has two red cable-activated emergency stop
devices that you can pull if you become trapped inside the APL. These
pull cords are located inside the front and rear doors and span the
length of the APL component.
Figure 28: Red cable-activated emergency stop device (top of picture)
Pulling a cable-activated emergency stop device stops APL operation
and activates the internal lights. You can then make your way to an exit
APL safety features
27
Summary of Contents for Magnus VLF Q2400
Page 2: ......
Page 4: ......
Page 6: ...vi Magnus VLF Q2400 Q3600 Platesetter Safety Guide for Operators ...
Page 14: ...8 Chapter 1 Introduction to safety information ...
Page 22: ...16 Chapter 2 Safe operation ...
Page 26: ...20 Chapter 3 Safe maintenance ...
Page 45: ...Figure 49 High touch current label Electrical hazards 39 ...
Page 46: ...40 Chapter 5 Hazards ...
Page 47: ......