NovaJet 800 Series Training Guide
4
6.
Attach dryer brackets and install dryer plenum.
Note: align the dryer plenum guide pins with the dryer brackets.
7.
Secure dryer logic cable and power cord.
NOTE:
If installing the new
universal dryer (black metal) ensure the underside voltage selector switch
is set to either 115VAC or 230VAC depending on region.
8.
Activate diagnostics ‘legs test’.
Ensure media rollers and dryer function normally. Both rollers should initially pulse in
one direction. By blocking either the top sensor or bottom sensor path the opposite
roller should reverse direction. Dryer should intermittent pulse every few seconds,
after 5 minutes the air leaving the dryer should be warm.
Prime
Color Calib Menu
Access Cartridge
Display Settings
Service Menu
Print Settings
Calibration Menu
Exit
Utility Menu
Calibration Menu
Diagnostics Menu
About
Exit
Service Menu
Servo PWM Test
Accessory
Menu
Servo Cycle Test
Carriage Test
Exit
Color Test
Continuous Test
Diagnostics Menu
Fan #1 Test
Fan #2 Test
Legs Test
Exit
Accessory Menu
1 Spare
Exit
Legs Test Menu
0 Unwind
0 Wind
1 Interlock
1 +24V Detect