Diagnostics and Troubleshooting
5-24
September 2000
910
Configuration file
field:_filename_is invalid.
Calibration will be cancelled.
The user manually edited a field
in a configuration file and entered
an incorrect value.
• Manually enter the correct
value.
• Reinstall the application.
• If problem continues, call for
service.
911
Error_errcode_occurred.
Processing stopped.
An internal error occurred with the
software.
Restart the application.
919
Error occurred preparing to
handle exit from Kodak
Calibration. Will not perform
cleanup at exit.
An internal error occurred with the
software.
Restart the application.
921
Unable to return the printer
to its original state. Fix
printer problem and re-
calibrate.
The application was trying to
cancel but received an error when
sending the original LUT back to
the printer.
Printer is in an unknown state.
Correct any printer problems and
restart the application.
922
There is already a printer
open. Please close the open
printer first.
User tried to open a printer when
the printer was already open.
Close the open printer.
923
An error occurred during the
loading of a printer. Please
check to make sure the file
chosen was of the correct
type and/or format.
An error occurred during the
loading of a printer.
Check that the file chosen was of
the correct format or type.
924
No printer loaded.
The operator has not yet opened
a printer.
Open a printer.
941
The height and width values
do not agree with the size of
the target file.
The specified size does not match
the file size.
Enter the correct file size.
942
Unable to configure
densitometer. Densitometer
configuration file may be
corrupt or lost.
The file CalDevDensGen2.cfg is
corrupt or lost.
Restart the application. If problem
continues, call for service.
1003
Unable to load default
configuration file:_filename_.
The default configuration file was
deleted or renamed or moved.
Restore the file manually or
reinstall the software.
1004
Unable to set values
in new configuration file.
An internal error occurred with the
software.
Restart the application.
1005
Unable to save configuration
file:_filename_.
The system is trying to save a file
but there is not enough disk
space.
Remove any unnecessary files to
increase free disk space.
1006
Configuration file field:_field_
is invalid.
The user manually edited a field
in a configuration file and entered
an incorrect value.
• Manually enter the correct
value.
• Reinstall the application.
1007
Unable to remove
directory:_directory_.
User does not have update
authority on the directory.
Verify that the user has authority
on the directory.
Error
Code
Error Code /Status
Message
Possible Cause/Subsystem
Possible Solution
Summary of Contents for PROFESSIONAL LED II 20P
Page 16: ......
Page 20: ......
Page 74: ......
Page 90: ......
Page 118: ......
Page 122: ......
Page 146: ...Additional Calibration Information C 12 September 2000 Value Graph ...
Page 147: ...Additional Calibration Information September 2000 C 13 Difference Graph ...
Page 168: ......
Page 190: ......
Page 197: ......