System Operating Procedures
3-10
September 2000
When the paper cassette is locked, you can turn on the room lights.
IMPORTANT: When moving the supply cassette, pick up and carry the cassette
by both handles to prevent the paper from sliding or “telescoping”
to one side.
Installing the Supply Cassette
1.
Open the sheet transport door and remove any chad. See "Removing the
Chad" on page 3-14.
2. Check the knife and, if necessary, remove the trail edge of the paper from the
previous roll through the chad area.
3. Close the sheet transport door.
4. Open the paper supply door.
supply cassette lock
knife
chad area
chad
sheet transport
door
paper supply door