Specifications
October 2002
B-5
Power Cords
A 2.4 m (8 ft.), grounded power cord with a special three prong plug is provided
with your printer. In addition, an 2.4 m (8 ft.), grounded power cord with a three
prong plug is provided with your processor. The printer conforms to the NEMA N6/
15 Printer Plug Specification. The processor conforms to the NEMA L14-30
Printer Plug Specification.
Special plugs and cords may be required outside of the United States and
Canada. These plugs and cords will be provided by the Kodak distributor (the
power cord provided for international locations must have at least 14 gauge wire
for the printer and 10 gauge wire for the processor).
The power cords should be certified and approved by a national test house.
For technical support, service, repair and fuse replacement information, contact
Eastman Kodak Company’s Technical Assistance Center at 1-800-822-1414.
CAUTION: Make certain nothing obstructs or is placed on power cords. Do
not use extension cords; they can cause voltage loss which may
result in unreliable equipment performance or equipment
damage.
Power Outlets
A separate, dedicated power line with a 208 V, 15 amp dedicated receptacle is
required for the printer.
A separate, dedicated power line with a 208 V AC, 30 amp dedicated receptacle is
required for the processor.
The outlets should meet the following standards.
Printer
Processor
amperage
15 amp
30 amp
wire size
14 gauge or larger
10 gauge or larger
phase
1 (single)
3 or 1
receptacle
NEMA5—N6/15
NEMA6—30R
impedance between
ground and neutral
wires
less than 2 ohms
less than 2 ohms
voltage drop across
the circuit breaker
less than 0.1 volts
less than 0.1 volts
distance between
receptacle and
equipment
1.5 m (5.0 ft.)
or less
1.5 m (5.0 ft.)
or less
Summary of Contents for Professional RP 50
Page 1: ...KODAK PROFESSIONAL RP 50 LED Printer Operator s Guide Part No 2J0686 ...
Page 16: ......
Page 74: ......
Page 90: ......
Page 118: ......
Page 122: ......
Page 146: ...Additional Calibration Information C 12 October 2002 Value Graph ...
Page 147: ...Additional Calibration Information October 2002 C 13 Difference Graph ...
Page 168: ......
Page 190: ......
Page 197: ......