Specifications
October 2002
B-9
Line Voltage
The printer and processor operate satisfactorily over a range of voltages around
the nominal voltage.
The local utility company is required to deliver power usually within ±10% of the
rated value to the main distribution panel in the building. Voltage then drops from
there to the outlets where the equipment is connected. The total voltage drop is a
function of the following factors:
•
The composition of the conductor material in the wire. Copper wire is a better
conductor than copper-clad aluminum and aluminum wire, which results in
less voltage loss over the same length of wire.
•
The diameter or gauge of the conductor. Large diameter conductor exhibits
less voltage loss than small diameter conductor.
•
The length of the circuit. A long circuit layout may result in more voltage loss
than a short, direct circuit layout.
•
The load or current on the circuit (amperes). A large circuit load may result in
voltage loss in a circuit.
•
The types and number of connections. Several connections in a circuit
increase the chance of improper wiring practices, which could result in
voltage loss.
You must allow for adequate wiring to keep the supplied voltage within the
required range. Otherwise, intermittent data errors and system errors may occur.
Low-voltage problems are more common than high-voltage problems and are
generally caused by poor wiring practices.
Summary of Contents for Professional RP 50
Page 1: ...KODAK PROFESSIONAL RP 50 LED Printer Operator s Guide Part No 2J0686 ...
Page 16: ......
Page 74: ......
Page 90: ......
Page 118: ......
Page 122: ......
Page 146: ...Additional Calibration Information C 12 October 2002 Value Graph ...
Page 147: ...Additional Calibration Information October 2002 C 13 Difference Graph ...
Page 168: ......
Page 190: ......
Page 197: ......