Operator Guide
33
Chapter 2. Operation
Print Station Operation
Status Screens
Status screens display when you select a function listed on the
Control
Menu
or
Service Menu
.
Status screens display information only; no control functions are available
on a status screen. Help information is available on any status screen
(press
F1
). Figure 2.14 shows the status screen format.
Figure 2.14
Status screen layout
Figure 2.15 shows an example status screen (
Printhead Ready
reached
from the
Control Menu
.)
Figure 2.15
Printhead Ready status screen
TITLE SECTION
STATUS AND MEASUREMENT SECTION
EYELID STATUS
FUNCTION/STATUS
TIME REMAINING
STATE NUMBER
HS SYSTEM STATUS COLUMN
MEASUREMENT COLUMN
MESSAGE COLUMN
Print Station # 1
Remote Eyelid
PRINTHEAD READY
Time: complete
Pr
ess ESC to return to previous MENU
State # 16
SYSTEM STATUS
MEASUREMENTS
MESSAGES
Fluid Servo ON
14.99
PSI
Vacuum Servo ON
10.0
In. Hg.
Printhead (S1000)
12345
Serial No.
Stim. Drive ON
0.299
Tab Vrms
Chg. Plt.Heater ON
Ready to Print
PntHd Ink/Amb. Temp.
29./27.
Deg. C
Charge Voltage ON
(130.7
Volts)
Ink Concentration OK
Ink Level OK
Off Line
Printhead Use
207.5
Hours
Exit Save
Print Station Use
1234
Hours