6.5.2 Alarm
Level
Using this function you can select the image color that activates the alarm.
CAUTION:
A weaker color than that specified does not activate the alarm
Initial setting: Red
Selective colors: 14 colors
6.5.3 Alarm
Length
This sub menu determines a vertical length of sounder image that activates the alarm.
Initial setting: Short
Selectable video length: 3 steps (Short, Medium and Long)
Short: 2 dots and more
Medium: 6 dots and more
Long: 10 dots and more
6.5.4
U Temp Alarm (Upper Temperature Alarm)
Temperature alarm: When temperature information from the KODEN temperature sensor (ST-80, 90 or
ST-100) or external temperature sensor falls within a preset temperature range, the audio alarm will be
activated.
The U Temp Alarm function sets up the upper limit of the temperature alarm range.
Initial setting: 0.0
o
C /
o
F
Selective range: 0.0 – 99.9
o
C /
o
F in 0.1
o
C /
o
F
6.5.5
L Temp Alarm (Lower Temperature Alarm)
The L Temp Alarm function sets up the lower limit of the temperature alarm range.
: Mod
MENU : Exit
0
0
0
0
MENU 2
MENU 1
STC Depth (L)
STC Amp (L)
Return
: MENU No. Select
MENU 3
MENU 4
MENU 5
MENU 6
MENU 7
STC Amp (H)
STC Depth (H)
Initial setting: 0.0
o
C /
o
F
Selective range: 0.0 – 99.9
o
C /
o
F in 0.1
o
C /
o
F step
6.6
MENU 3 (STC adjustment)
Using MENU 3, the following items can be adjusted.
1. STC Depth for High Frequency picture.
2. STC Amplitude for High Frequency picture.
3. STC Depth for Low Frequency picture.
4. STC Amplitude for Low Frequency picture.
Figure 6.4 Menu 3 display
93132902-00