5)
This picture is the view of the inside of the
scanner unit housing.
(
a
)
Cable holding plate
(
b
) Cable clamp-b
(
c
) Cable clamp-c
(
d
) Cable clamp-d
6) Remove the fixing two bolts.
(Tool: Wrench 8mm)
Remove cable holding plate and
rubber packing.
7) The connecting cable CW-845-xxM
Blue tapes are
wound as a mark on the cable.
8) Pull
in the connecting cable into the scanner unit
through the cable inlet hole.
Guide the cable to the cable holding plate.
(
a
)
(
b
)
(
c
)
(
d
)
Cable holding plate
Fixing bolt (8mm)
Rubber packing
Blue tape mark-b
Blue tape mark-a
Blue tape mark-c
Connecting cable
Cable inlet hole