MDC-7000/7900 Series
Chapter 7 Input/output data
0092669002-07
7-17
7.4.3 VDR (external monitor) and Alarm output signal specification
Output connector name: VDR & Alarm
Connector used: BU-10PMMP-LC7001
Connector acceptable: BU-10BFFA-LL7001
Pin location is shown below.
Signal specification
This RGB output is compliant with the image test defined in the VDR test standard IEC61996.
VDR output cannot be deactivated by the user.
Signal name
Frequency
Polarity
Signal width Level
Impedance
Horizontal sync signal
(H-SYNC)
63.981 kHz
Negative
1.037
μs
TTL
200 Ω
Vertical sync signal
(V-SYNC)
60.0 Hz
Negative
47
μs
TTL
200 Ω
R, G, B Video signal
-
Positive
-
0.7 V p-p
75 Ω
Alarm output
-
-
Contact*
-
Capacity 1A
*
Alarm contact will close in case of failure.
7.4.3.1 Circuit for horizontal sync, vertical sync signal output
7.4.3.2 Circuit for R, G, B video signal
Pin number
Signal name
1
RVD
2
R-GND
3
GVD
4
G-GND
5
BVD
6
B-GND
7
H-SYNC
8
V-SYNC
9
ALARM
10
ALARM
RVD/GVD/BVD
GND
R, G, B Video signal
Ground
75
GND
TC74VHC08
Horizontal sync,
vertical sync signal
Ground
H-SYNC/V-SYNC
75
LMH6683
J1
External monitor and alarm output connector pin
assignment
(Display unit upper view)
1
2
3
4
5
6
7
8
9
10
External monitor and alarm output
connector pin assignment
Summary of Contents for MDC-7006
Page 1: ......
Page 2: ......
Page 44: ...Chapter 3 installation method MDC 7000 7900 Series 3 24 0092669002 07 Unit mm inch MRM 108 ...
Page 96: ... This page intentionally left blank ...
Page 134: ... This page intentionally left blank ...
Page 155: ...0092669002 07 A 1 INTER CONNECTION DIAGRAM RB807 ...
Page 156: ...A 2 0092669002 07 INTER CONNECTION DIAGRAM RB808 ...
Page 157: ...0092669002 07 A 3 INTER CONNECTION DIAGRAM RB809 ...
Page 158: ...A 4 0092669002 07 INTER CONNECTION DIAGRAM MRD 108 MRO 108 ...
Page 159: ...0092669002 07 A 5 INTER CONNECTION DIAGRAM MRM 108 MRO 108 ...
Page 160: ......