MDC-7000/7900 Series
Chapter 3 Installation method
0092669002-07
3-37
3.4.7 AIS cable connection
3.4.8 GPS compass connection
Figure 3.21 Cable connections for KODEN GPS compass
CW-376
or
CW-373
GPS
Compass
J7
J5
J6
J6 (SDME)
The GPS Compass made by KODEN is connected to J6 (SDME) connector.
After installation, initialize GPS compass from radar menu to set the format (baud rate) and
output sentences.
Refer to
“4.2.3.1 Connection of KODEN GPS compass”.
Figure 3.20 Cable connections for AIS
1
7
2
3
4
8
6
5
Pin
No.
CW-387 Wire color
Signal name
1
Shield
Frame ground
2
Blue
Twist
cable
IN-A
3
White
IN-B
4
Yellow
Twist
cable
OUT-B
5
Brown
OUT-A
6
Green*
GND
7
Red
Twist
cable
NC
8
Grey
NC
Pin 1 Indicated
AIS Cable connector pin assignment
Serial signal
IEC 61162-2
CW-387-5M
J2
*Green/Black twisted cable (Black is not used.)
Summary of Contents for MDC-7006
Page 1: ......
Page 2: ......
Page 44: ...Chapter 3 installation method MDC 7000 7900 Series 3 24 0092669002 07 Unit mm inch MRM 108 ...
Page 96: ... This page intentionally left blank ...
Page 134: ... This page intentionally left blank ...
Page 155: ...0092669002 07 A 1 INTER CONNECTION DIAGRAM RB807 ...
Page 156: ...A 2 0092669002 07 INTER CONNECTION DIAGRAM RB808 ...
Page 157: ...0092669002 07 A 3 INTER CONNECTION DIAGRAM RB809 ...
Page 158: ...A 4 0092669002 07 INTER CONNECTION DIAGRAM MRD 108 MRO 108 ...
Page 159: ...0092669002 07 A 5 INTER CONNECTION DIAGRAM MRM 108 MRO 108 ...
Page 160: ......