Chapter 5 Equipment
MDC-900 Series
5-6
0093142132-05
Cable Connection
Radome Antenna (2kW)
1.
Confirm that the power of the scanner unit is turned off.
Install the cable to the connector J5 at the rear of the
display unit.
2.
Next, remove the upper radome of the scanner unit,
lifting upward not to touch the aerial inside.
(3 pieces of fixing screw)
3.
Peel off the tape fixing the aerial.
4.
Remove the shield cover at the stern side. (3 pieces of
fixing screws)
Rotating base
Flat washer
Spring washer
Installation bolt
Antenna radiatyion side
(KODEN –mark side)
Antenna
Rotating base
Remove
Protective cap
Projection mark
Installation of cover (2kW radome)
Install with three bolts.
HDG
Logo sheet is affixed to the side.
Summary of Contents for MDC-900 Series
Page 1: ......
Page 2: ......
Page 72: ...Chapter 6 Attached Table MDC 900 Series 6 2 0093142132 05 ...
Page 75: ...MDC 900 Series Chapter 6 Attached Table 0093142132 05 6 5 6 3 External View ...
Page 83: ......