Fault Code
Main Reason
Solution
E01
The wire from
computer to bottom
control board isn’t
properly connected
1.
Check the connection wire between
computer and control board was well
connected.
2.
Make sure the IC on the control board was
well inserted. If not re-insert.
3.
Abnormal power supply in control board.
Please change a new control board.
E02
Short Circuit
1.
Bad contact with motor open circuit. Please
change a new motor or check the
connector.
2.
Power cord was puncture. Please change a
new power cord or control board.
E05
Over Current
Protection
1.
Overloaded.
2.
Running board with heavy resistance.
Needs to be oiled.
3.
Damage in Motor. Replace motor.
E06
Control Board Self-
Checking
E08
EEPROM Damage
Change the control board