background image

Function buttons(continued)

TIMRT OFF Button    

 

LOCK Button    

 

5

6

Model: R51I13/BG(C)E,
            R51I15/BG(C)E.
            

NOTE:

 R51I15/BG(C)E 

models hav e no SWING
feature.

TEMP

AUTO 
COOL
DRY
HEAT

FAN
HIGH
MED
LOW

MODE

FAN SPEED

SWING

TIMER ON

ECONOMY

ON/OFF

TIMER OFF

RESET LOCK

SET TEMPERATURE(   F)

        LED
    DISPLAY

NOTE: 

While the unit is running under Energy-saving

mode, it would be cancelled if any other buttons are 
pressed.

10

Press this button to activate the Auto-off time 
setting. Each press will increase the time setting
in 30 minutes increments, up to 10 hours, then at
1 hour increments up to 24 hours. To cancel the 
Auto-off time setting, just press the button until 
the time setting is 0.0.

11

Press this recessed button to lock all current 
settings, and the remote controller will not accept 
any operation except that of the LOCK. Use the 
LOCK mode when you want to prevent settings 
from being changed accidentally. Press the LOCK 
button again to cancel the LOCK function. A lock 
symbol will appear on the remote controller display 
when the lock function is activated.

TIMER ON OFF

SET TEMPERATURE

Transmission Indicator

Temp./Timer  display

FAN SPEED display

MODE display

ON/OFF display

This transmission indicator will light when remote 
controller transmits signals to the indoor unit.

Displays the current selected mode. Including AUTO, 
COOL, DRY, HEAT (cooling & heating models only) 
and FAN.

O

O

The temperature setting (from 17 C(62  F) to 

O

O

30 C(88 F)) or timer setting (0~24h) will be displayed. 
If FAN mode is selected, there will be no display.

This indicator will be displayed when
 the unit is operating.

Displays the selected fan speed: AUTO, HIGH, 
and LOW. Nothing displays when the fan speed is 
selected in AUTO speed. When AUTO or DRY Mode
is selected, there will be no signals displayed.

MED 

This display area shows the settings of the TIMER. 
That is, if only the Auto-on time function is set, it will 
display TIMER ON. If only the Auto-off  time function 
is set, it will display TIMER OFF. If both functions are 
set, it will display TIMER ON OFF which indicates you 
have chosen both the Auto-on time and Auto-off time.

LOCK display is displayed when pushing the LOCK  
button. Push the LOCK button to clear display.

MODE display

(FAN mode)

TIMER display

LOCK Indicator

Indicators on LCD

 Press this button to clear the display on the 
 indoor unit, press it again to light the display .

LED Display Button    

 

12

TEMP

AUTO 
COOL
DRY
HEAT

FAN
HIGH
MED
LOW

MODE

FAN SPEED

SWING

TIMER ON

SLEEP

ON/OFF

TIMER OFF

RESET LOCK

SET TEMPERATURE(   F)

        FOLLOW
             ME

        LED
    DISPLAY

ION

13

Press this button to initiate FOLLOW ME function.
When the Follow Me  function is activated, the 
remote display is actual temperature at its location. 
The remote control will send this signal to the air 
conditioner every 3 minutes interval until press 
the Follow Me button again. 
The Follow Me function is not available under 
DRY and FAN mode.
Switch the operation mode or turn off the unit will 
cancel the follow me function automatically.

FOLLOW ME Button

Model: R51I17/BG(C)E

13

14

 When push this button, the ion generator is 
 energized and will help to remove pollen and
 impurities from the air.

14

ION Button    

 

9

Summary of Contents for KAACH12PORA

Page 1: ...WKZ USER MANUAL...

Page 2: ...rs your health when hazardous substances leak into the ground water and find their way into the food chain When using this air conditioner in the European countries the following informa tion must be...

Page 3: ...rules Suggested tools for window kit installation 1 Screwdriver medium size Phillips 2 Tape measure or ruler 3 Knife or scissors 4 Saw In the event that the window kit needs to be cut down in size bec...

Page 4: ...ts in a range of 17 C 62 F to 30 C 88 F or the TIMER setting in a range of 0 24hrs 6 UP and DOWN button NOTE The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius T...

Page 5: ...Start Stop timed program When the malfunction E1 E2or E4 occurs the Auto Start Stop timed program will also be cancelled SLEEP operation The air conditioner will control room temperature automatically...

Page 6: ...air inlet or outlet of the unit Allow at least 30cm of space from the wall for efficient air conditioning Your window slider kit has been designed to fit most standard Vertical and horizontal window a...

Page 7: ...me to use the machine take the exhaust hose out as shown in Fig 18 1 Install the adaptor B and adaptor I onto the exhaust hose as shown in Fig 19a or Fig 19b Refer to the previous pages for window kit...

Page 8: ...upper filter tab Fig 26 pull the filter out then up Remove the lower filter by loosening the screws taking down the air inlet grille then removing the air filter as shown in Fig 27 28 Cleaning Wash t...

Page 9: ...ature Cooling mode The windows or doors in the room are not closed There are heat sources inside the room Exhaust air duct is not connected or blocked Temperature setting is too high Air filter is blo...

Page 10: ...AIR CONDITIONER REMOTE CONTROL...

Page 11: ...e indoor unit is exposed to direct sunlight the air conditioner may not function properly Use curtains to prevent the sunlight from falling on the receiver If other electrical appliances react to the...

Page 12: ...g 3 MODE Button 3 4 TEMP AUTO COOL DRY HEAT FAN HIGH MED LOW MODE FAN SPEED SWING TIMER ON ECONOMY ON OFF TIMER OFF RESET LOCK 1 2 4 3 6 5 7 8 9 10 11 SET TEMPERATURE C LED DISPLAY 4 SWING Button on s...

Page 13: ...d If FAN mode is selected there will be no display This indicator will be displayed when the unit is operating Displays the selected fan speed AUTO HIGH and LOW Nothing displays when the fan speed is...

Page 14: ...start the air conditioner 3 1 2 1 In the Auto mode the air conditioner can logically choose the mode of Cooling Fan Heating and Dehumidifying by sensing the difference between the actual ambient room...

Page 15: ...s in 30 minutes increments up to 10 hours then at 1 hour increments up to 24 hours 3 After setting the TIMER OFF there will be a one half second delay before the remote controller transmits the signal...

Page 16: ...Example TIMER ON TIMER OFF Off Start Stop operation This feature is useful when you want to start the air conditioner before you wake up and stop it after you leave the house To start the air conditio...

Reviews: