Installation heights

–  Over gas and electric cookers, 

Kogan 

recommends 

our rangehoods to be mounted

at a height of between 600-800mm above the 

cooking surface.

–  Electric cooktops must have a minimum height of 

600mm from the underside of the rangehood to the 

cooktop face.

–  Gas cooktops must have a minimum of 650mm from 

the burner to the underside of the rangedhood.

–  It is not recommended to install the rangehood 

outside or over open flame grillers or barbecues. 

Installing the rangehood 

Way one:

–  

To install onto the wall drill 2 holes of Ø8mm on a

suitable place according with the centre distance of

hole in the back of the cooker hood.

Insert the nut into the holes.

nsert the screws into the nuts and tight. Put the

cooker hood onto the tighten screws.

–  

Fix the cooker hood with safety screw. The two safety

vents are positioned on the back casing, with diameter

of 6mm.

Put the one way valve onto the cooker hood.

Drill 4 holes of 6mm diameter at the bottom of the

hanging cupboard.

Put the one way valve on the cooker hood, then install

the cooker hood on the bottom of the hanging

cupboard, tighten the hood with enclosed 4 screws.

INSTALLATION INSTRUCTIONS 

CONTINUED

The extensible pipe are optional accessory, not 

supplied.
Take off protection film before installation.

There are 2 methods for ventilation , including ' 

horizontal ventilation' and ' vertical ventilation'. Please 

pay attention to the ventilation method when installation.

Vertical ventilation: See Pic A, please use tool take out 

the round cover before using, and the air can be vented 

from top.

horizontal ventilation: See Pic B, please use tool take out 

the rectangular cover before using, and the air can be 

vented from back.

The rectangular air outlet for horizontal ventilation is not 

supplied.

 

Way 

Air ventilation setting

Outdoor exhausting: Turn the adjuster to outdoor 

position, install the outlet,

 turn on the cooker hood, then 

the air will be vented from the outside outlet.

Recycling: the recycling mode with carbon filter ,Turn the 

adjuster to indoor position, install the outlet cover, turn on 

the cooker hood, then the air can be vented from the 

inside outlet.

Note: The charcoal filter is mounted on the back of the 

grill and must be changed once three month.

Warning: the charcoal cannot be washed or recycled. It 

should be changed at most after 120 hours using. The 

carbon filter shouldn’t be exposed to heat.


two:

Insert

NOTE: Carbon Filter not included.

Summary of Contents for KAFIXEDRNGA

Page 1: ...60cm Fixed Rangehood INSTRUCTION MANUAL INSTALLATION MANUAL MODEL KAFIXEDRNGA ...

Page 2: ...CONTENTS General Safety Warnings 3 Your Rangehood 5 Operating Your Rangehood 6 Installation Instructions 7 Cleaning Maintenance 9 Troubleshooting Technical Data 10 Warranty 11 ...

Page 3: ...lug do not pull by the cord when disconnecting USAGE CONDITIONS AND RESTRICTIONS Domestic use only This rangehood is designed for indoor domestic use only It can be built into a standard kitchen cabinet or housing unit following the installation instructions in this manual Intended purpose Only use this rangehood for its intended purpose in its intended environment and as described in this manual ...

Page 4: ... capabilities or lack of experience and knowledge unless they have been given supervision or instructions concerning use of the appliance by a person responsible for their safety Children Supervise young children to ensure they do not play with the appliance Never allow children to operate or play with the rangehood Never Flambé under the rangehood Note Exhaust air must not be discharged into an e...

Page 5: ...r Kogan Rangehood is supplied with 1 Rangehood 1 Packet of fasteners and wall plugs 1 120mm Air outlet 1 Outlet cover Typical installation tools required You ll most likely require the following tools equipment not supplied for the installation of your rangehood Electrical drill Tape Measure Screw driver Spirit Level If ducting your rangehood you ll also most likely require Jig saw Ladder Duct tap...

Page 6: ...nd cooking which does not make much steam Medium Speed button This is ideal for standard cooking operation High Speed button When a high density of smoke or steam is produced use this speed for the highest effective ventilation Light button Pressing this turns the lighting on or off Note If Low Medium High speed buttons are press at the same time the unit will only operate at the highest speed OPE...

Page 7: ...nsure that the side outlet grilles are not obstructed in any way as this will effect the efficiency of the rangehood Ensure that the rangehood is mounted in a level position both horizontally and vertically This is essential to ensure the rangehood operates correctly and prevents grease build up at one end Ducting options Before beginning the installation of your rangehood the method of ducting sh...

Page 8: ...board tighten the hood with enclosed 4 screws The extensible pipe are optional accessory not supplied Take off protection film before installation There are 2 methods for ventilation including horizontal ventilation and vertical ventilation Please pay attention to the ventilation method when installation Vertical ventilation See Pic A please use tool take out the round cover before using and the a...

Page 9: ...ng would be cleaned away Cleaning the cooker hood To protect the main body of your rangehood from corrosion or stains the cooker hood should be cleaned with hot water with a non corrosive detergent every two months For stubborn stains or marks you can try using a specific stainless steel cleaner available from most supermarkets Warning Please do not use a corrosive detergent or abrasive clothes as...

Page 10: ...a repair This includes situations where the rangehood has been tiled in or sealed in with a sealant Please refer to the conditions of that appear on the warranty card at the rear of this user manual Fault Common Cause Common Solutions The lights work however the motor does not work The motor is blocked or jammed or the capacitor is damaged Call the Support team for further guidance The capacitor d...

Page 11: ...lia is not liable in the following situations which are not exhaustive a the Appliance is damaged by i accident ii misuse or abuse including failure to properly maintain or service iii normal wear and tear iv power surges electrical storm damage or incorrect power supply v incomplete or improper installation vi incorrect improper or inappropriate operation vii insect or vermin infestation viii fai...

Page 12: ...12 ...

Reviews: