Battery Notes

:

We recommend the use of alkaline batteries with the air conditioner. Do not use

 

rechargeable

 batteries.

When replacing the batteries, replace both at the same time. Do not mix old and 
new batteries.

If the air-conditioner and remote control is not being used for a long time, 
remove the batteries from the remote control.

Battery Warnings

:

If there is a battery leak, do not touch the battery with your bare hands.
Chemicals inside the battery may cause burns and other health hazards; if the battery 
liquid flows through onto your skin or clothing, rinse with water immediately; if it gets 
into your mouth, gargle with water and go straight to a hospital for urgent examination.

Protection Functions

Anti-Freeze Protection Function

Upon cooling, after the compressor has been operating for more than 10 minutes and 
the pipe temperature gets to 2°C or below continuously for 20 seconds, the 
compressor and water pumping motor will turn off and the LED display will show E4.  
The unit will initiate the anti-frost protection function and all buttons will be inactive 
(except for the OFF button).  Once the pipe temperature rises to 8°C or above, the 
protection function will cease and the unit will meet the requirement for a 3-minute 
delay protection of the compressor.

Full Water Protection Function

When the water in the water tray exceeds the alarm level, the unit will sound an alarm 
automatically and the full water indicator will illuminate. In this case, you will need to 
drain the condensate from the unit, otherwise the unit will shut down automatically 
after the buzzer has sounded 5 beeps. (For more information regarding draining the 
tank, see the section "Drainage Method").
If the unit is not shut down manually, the unit will be restored to the previous operating 
status automatically once the water is fully drained. Otherwise the power can be 
restored and the unit usage can resume.

Delay Protection Function of the Compressor

This unit offers restart protection for the compressor. The compressor may start 
immediately upon first use, however if it has been running and shut-down for any 
reason, a 3-minute delay will be enforced before the compressor can then be started up
again.

7

Summary of Contents for KAPORAIR10GA

Page 1: ......

Page 2: ...etting 4 Buttons 4 Product Usage 5 Placement 5 Installation 5 Remote Control 6 Protection Functions 7 Anti Freeze Protection Function 7 Full Water Protection Function 7 Delay Protection Function of th...

Page 3: ...itself and remove Never pull on the cord itself to unplug an electrical device Do not operate the unit by turning the power supply on or off at the wall nor by simply plugging and unplugging the power...

Page 4: ...ter 20 Radiating Fine Mesh 7 Top Casing 21 Condenser Filter Mesh 8 Horizontal Louvre Connecting Lever 22 Condenser Filter Frame 9 Main Vertical Louver 23 Base Plate 10 Front Casing 24 Remote Control 1...

Page 5: ...ting you can press this to set a time for the unit to turn itself off Once the time set has passed the unit will automatically shut down If this button is used while the unit is not operating it serve...

Page 6: ...Installation of the Heat Exhaust Hose 1 Pull the end of the heat exhaust hose apart by several segments 2 Hold the end handle of the C shape bracket of the heat exhaust hose in your left hand and the...

Page 7: ...elliptical hole in the window sealing board assembly as shown below Note The flat end of the heat exhaust hose must be in position The heat exhaust hose should be kept as short and free of bends as p...

Page 8: ...itiate the anti frost protection function and all buttons will be inactive except for the OFF button Once the pipe temperature rises to 8 C or above the protection function will cease and the unit wil...

Page 9: ...cap are in position or else the condensate from the unit will drain out onto the floor or carpet Continuous Drainage Method 1 Unscrew the drain cap in the direction shown by the arrow above and unplug...

Page 10: ...y a nice even amount of force to avoid twisting or damaging the frames Be sure to take out the filter frame first followed by the filter mesh 3 Put the evaporator filter frame condenser filter frame a...

Page 11: ...o air circulation mode with a low fan speed and leave it running in this mode for at least 8 hours to ensure the interior of the unit completely dries to prevent mold 4 Turn the unit off unplug the po...

Page 12: ...tomer support team Problem Possible Cause Solution Suggestion Air conditioner does not work No Power Check power socket is plugged in and turned on Screen displays FL Check that water tank isn t full...

Reviews: