Locations to avoid
Do not locate smoke alarms:
•
In turbulent streams of air such as near fens, heaters, doors and windows, etc These
can draw smoke away from the alarm.
•
In high humidity areas such as bathrooms and shower rooms as high humidity can
trigger the alarm, or where temperature exceeds 40 °C or below 0 °C.
•
At the apex of an "A" frame ceiling. "Dead air* at the top may prevent smoke from
reach ing the a la rm i n ti me to provide ea rly wami ng.
•
Less than 300mm (12 inches) from the wall when mounted on the ceiling.
•
In insect-infested areas, Tiny insects may affect performance.
•
In kitchens, boiler rooms, laundry rooms, garages, Combustion particles from cooking or
car exhausts and dust and moisture could trigger the alarm.
•
In very dusty or dirty areas, Dirt and dust can build up and impair performance.
•
Within 300mm (12 inches) of light fittings or room corners,
•
In locations which would make routine testing or maintenance hazardous (eg,over a
stairwell).
•
On poorly insulated walls or ceilings.
•
Near objects such as ceiling decorations which might impede the path of smoke to the
alarm.
•
Within 1500mm (5 feet) of fluorescent light fittings.