background image

1. Nozzle

2. Pin

Shape of nozzle 
insertion port 

6. Installation, Wiring and Tubing

6.1 Installation

CAUTION

DTY-ELK01-L  (low-dust  type)  uses  clean  room  packaging.  Always  open  the 
packaging in a clean room environment.
A nozzle is not included with the product (exception: installed in the air-saving type).
Separately purchase a nozzle matching your utilization.
Nozzles are made specifically for each type. Always use the right nozzle for each 
type.

1) Attach the nozzle to the m ain unit, and use the pin provided with the nozzle 

to fix it to the main unit.

* To replace the nozzle, pull out the pin and then rem ove the nozzle.

WARNING

Check that the nozzle is securely inserted and securely held in place by the pin. If 
not perfectly set, the nozzle could come loose during use, damaging the product and 
equipment.

CAUTION

The  nozzle  insertion  part  is  made  in  a  D-shaped  cut  to  prevent  rotation.  When 
attaching, align the main unit nozzle insertion port with the nozzle insertion part.

2) W hen  using  the  mounting  bracket  for  installation,  use  the  two  mounting 

bracket  screws  (enclosed  with  the  packaging)  to  mount  the  mounting 
bracket to the main unit.

CAUTION

Tightening torque for mounting the bracket to the main body should be 50 N

cm 

or less.

3) Use the m ounting holes on the side of the main unit (3-

3.4) or the mounting 

holes in the mounting bracket (4-

3.4) to fix the product in place.

* Provide the mounting screws separately.
4) If using a tube, insert the tube firmly all the way to the base of the nozzle.
5) If using a nozzle and tube capable of adjusting the ionized air blow direction, 

fix  the  nozzle  so  that  the  ionized  air  blow  port  is  pointed  toward  the  static 
charge removal target.

6) If using  a tube-tip nozzle,  firmly insert the tube-tip nozzle into the tube, and 

use the bracket provided to fix it in place.

* For details, refer to the Instruction Manual provided with the tube-tip nozzle.

CAUTION

As  piezoelectric  ceramic  is  built  into  the  main  unit,  do  not  apply  shocks  due  to 
dropping or vibration, etc. Such action could result in product malfunction.
The various tubes used for the standard nozzle are consumable items that require 
periodic replacement.
When bending the bender nozzle, maintain the base of the bender nozzle in place. 
The main body could be damaged.
Do  not  use  nozzles  not  specifically  designed  for  the  unit.  Also,  do  not  make 
modifications  to  the  nozzle.  Such  action  could  be  the  cause  of  product 
malfunctions, function shutdown, or damage.
Do  not install in locations  prone  to  condensation,  or subject to large  humidity  and 
temperature swings. The product could be subjected to damage.

<W hen using the nozzle unit for the bender nozzle>
1) Rem ove the tip of the bender nozzle.
2) Always tighten the various nozzle units securely to the bender nozzle.

CAUTION

Hold the pipe portion securely when removing the tip of the bender nozzle.
The  recommended  tightening  torque  for  the  nozzle  unit  used  for  the  bender 
nozzle is 30 N

cm.

3)  To  adjust the direction  of the bar nozzle unit (DTRY-ADN-

00B) ionized air 

blow port, loosen nut B.
To  adjust  the  direction  of  the  flat  nozzle  unit  (DTRY -ADN-FT01)  attach  the 
ionized air blow port at the tip, and use the lock nut to fix in place.

CAUTION

When  loosening  nut  B,  be  sure  that  nut  A  is  fixed  in  place,  and  check  that  no 
force is being applied to the bender nozzle.

6.2 W iring
1) Use  the  power  signal  cable  provided,  and  connect  as  shown  in  the  figure 

below.
If  taking  power  from  input  100VAC,  use  the  AC  adaptor  (DTY-ZKPS),  sold 
separately.

CAUTION

Securely connect the ground wire (with a grounding resistance of 100

Ω

or less). 

Otherwise, ionizer performance may not be adequate.
Securely insert the connector.
Contact capacity for each output is 24V 50 mA  MAX. Check the capacity of the 
connected equipment before use.
When selecting a power supply for use with this product, always use one that has 
been  certified  by  the  EU  Notified  Body  (as  a  limited  power  source  defined  in 
IEC/EN60950-1 or IEC/EN61010-1), or the optional AC adapter.
0VDC, F.G, nozzle and mounting bracket are connected to the internal circuit. 
Use a  mechanical  switch,  photo  coupler,  or  relay  for  external  input.  If  the 
grounding potential of the external device to be used and the grounding potential 
of this product are different, the  external device should have an insulated on/off 
procedure for the 0V line.

I/O Circuit Diagram

*

-

show the main unit pin number.

* Note in parentheses ( ) shows the lead wire color in the power signal cable.
* Use a no-voltage contact point or NPN open collector to connect 

H.V OFF.

(when 

0VDC shorted, discharge OFF)

* W hen  discharge  OFF  (when 

H.V  OFF  and 

0VDC shorted), H.V  LED 

goes OFF.

No.

Signal

Function

24VDC

Power input 24VDC±5%

0VDC

Power 0V and output 0V

H.V OFF

Discharge OFF when shorted at 

ALARM NC

Contact point output when performance 
malfunction occurs
(b contact point 24VDC 50 mA MAX)

ALARM NO

Contact point output when performance 
malfunction occurs
(a contact point 24VDC 50 mA MAX)

CHECK NO

Contact point output when abnormal 
discharge occurs
(a contact point 24VDC 50 mA MAX)

F.G.

Functional earth (with a grounding 
resistance of 100

Ω

or less)

CAUTION

The  abnormality output  circuit  of  this  product  will  be  active about  one second  after  the 
power is switched on. Sufficient care should be taken to design an error detection circuit 
during installation.
When the power to the main  unit of the ionizer is switched ON immediately  after being 
switched OFF, an abnormality output may occur. When performing such an operation, be 
sure to wait for a period of at least one second after switching off.
When the ionizer main unit is switched OFF, an abnormality output may occur. Pay careful 
attention to the design of the error detection circuit not to detect the ionizer’s abnormality
output for a one-second period after the power supply to the ionizer main unit is switched 
OFF.

6.3 Air Tubing
1) Connect  air  tubes  (outer  diam eter 

6 mm) to  the  DTY-ELK01  and 

DTY-ELK01-S main unit air fittings.
For DTY-ELK01-L, use fittings that match the tubing used (port size: Rc1/8).

2) Use a regulator to connect the air tube to the air source.

WARNING

Always  supply  air  before  switching  ON the  power,  and  use  within  the  specified 
pressure range.

CAUTION

Although  the  DTY-ELK01-L  (low-dust  type)  is  subjected  to  clean-room  cleaning 
and  packaging  using  clean  air  at  time  of shipping,  the  effects  of  vibration,  etc., 
during transport can generate particles. Flush out the unit and clean it thoroughly 
before commencing initial use.
For  connection  to  or  replacement  of  a  DTY-ELK01-L  (low-dust  type)  fitting, 
proceed  by  holding  the  female  screw  (Rc1/8)  hexagonal  part  in  position. 
Application of excessive force to the main unit could cause damage to the main 
unit.

7. Operating 

7.1 Steps W hen Starting Operation
1) Check that the nozzle  and discharge  needle unit  are co rrectly connected to 

the ionizer.

2) Check the ionizer wiring and air tubing.
3) Supply air to the unit from the air equipment that is being used.
4)  Supply  24VDC  power  to  the  unit.  The  POW ER  LED  and  H.V LED  on  the 

unit light up and electrostatic eliminati on begins.

* If the optional power adapter is used, supply 100-240VAC, 50/60 Hz.
*  W hen  using  external  controls  (H.V  OFF)  to  control  the  unit,  the  H.V  LED 

goes OFF when discharge is OFF.

* Use the input power side (24VDC side) to switch power ON/OFF.

WARNING

Take  soundproof  measures,  such  as  wearing  earplugs,  when  working  at  close 
proximity to the unit.

7.2 Steps W hen Stopping Operation
1) Stop the supply of power to the unit.
2) Stop the supply of air.

CAUTION

If the POWER LED is not illuminated or if the CHECK LED or ALARM LED lights up, 
immediately shut off the power and air, and see “6. Installation, Wiring and Tubing” in 
this  manual.  If  problems  still  do  not  resolve,  see  “8.  Maintenance”  and  “9. 
Troubleshooting” in this manual.

8. Maintenance

If  the  discharge  needle  is  soiled,  the  electrostatic  elimination  effects  will  be 
reduced.  Periodically  clean  the  discharge  needle  and  surrounding  area  to 
maintain performance.
<Discharge needle unit cleaning m ethod >
1) Rotate the discharge needle unit counterclockwise, and pull it from the main 

unit.

2) Rotate  the  discharge  needle  unit  bushing

counterclockwise, and rem ove the bushing.

CAUTION

Do  not  apply  excessive  force  when  removing  the  bushing  from  the  discharge 
needle unit.
The discharge needle unit could be damaged.
When  replacing  the  discharge  needle  unit,  use  the  specified  discharge  needle 
unit. Discharge needle units are specifically designed for each type.
You can determine the correct discharge needle unit by its color.

3) W hen the discharge needle unit has been rem oved, use a cotton swab 

soaked in anhydrous alcohol (IPA) to clean the discharge needle and 
bushing.

4) After  drying  the  unit  carefully  with anhydrous  alcohol,  reassemble  the 

discharge  needle  unit  onto  the 
main unit in reverse sequence to 
removal.
At  this  time,  rotate  until  the 

mark on the side of the main unit 
is aligned with the 

mark on the 

discharge needle unit.

WARNING

As the tip of the discharge needle is very sharp, care is needed when removing 
the  discharge  needle  and  during  cleaning. The  needle  tip  can  cause  injury.  In 
addition, be extremely careful to avoid bending or breaking the discharge needle.
Performance will be affected.
Securely attach the bushing and the discharge needle unit.
If  not  securely  fixed  in place,  performance  will  be  affected,  and  the  discharge 
needle unit may  become loose during use, causing damage to the  product and 
equipment.

CAUTION

To maintain performance, be sure to perform cleaning of the discharge needle and 
the surrounding area periodically. Performance will be affected, and lack of cleaning 
may cause damage to equipment and workpieces.
When performing maintenance, always disconnect the connection cables before 
proceeding.
When  using  alcohol  or  similar  substances,  make  sure  that there  is  adequate 
ventilation. In  addition,  always  thoroughly  dry  off  the  alcohol  after  using  it  for 
cleaning, and check that none has spilled on to the main unit.
Because  it  can  result  in  damage  to  the  main  unit,  absolutely  never  use  a  wire 
brush for cleaning.

<Main unit filter replacement method>
For DTY-ELK01-S, a filter is installed on the outside air intake port.
A dirty filter will result in reduced outside air intake efficiency, and static  charge 
removal perform ance will become inadequate.
Replace the filter if it has becom e dirty.
1) Rem ove the pin fixing the nozzle in place.
2) Pull out the filter in the nozzle direction.

If difficult to remove, use a precision 
screwdriver or tweezers.

3) Insert the new filter so that it slips in from the

nozzle direction, and then rem ount the pin.

9. Troubleshooting

If product operation appears to be abnormal, immediately shut off the power to 
the  m ain  unit,  disconnect  the  connection  cable  from  the  m ain  unit’s  power 
connection  terminal,  and  check  the  ite ms  in  this  section. If  the  abnormal 
situation  continues,  it may  mean  that  a  breakdown  has  occurred. Contact  the 
outlet  (the  agency) at  which  you  purchased  the  product,  or  the  nearest 
Koganei service station.

The POWER LED does not light up.

→ Verify that the wiring and power source are connected correctly.

The POWER LED lights up but the H.V LED does not.

→ Verify that the H.V OFF terminal is not shorted.

CHECK LED and ALARM LED are illuminated.

→ Verify that the unit is securely grounded.
→ Verify whether the discharge needle is soiled or damaged, and whether the 

surrounding area is soiled. If it is soiled, see “8. Maintenance” in this manual, 
and perform maintenance or replacem ent of the discharge needle unit.

No electrostatic elimination effect

→ Verify that ionized air is blown to the object eliminating static electricity. 
→ Verify whether the discharge needle is soiled or damaged, and whether the 

surrounding area is soiled. If it is soiled, see “8. Maintenance” in this manual, 
and perform maintenance or replacem ent of the discharge needle unit.

Any other abnormal condition

If  any  other  abnormal  condition  has  been  observed,  immediately  turn  off  the 
power  from  the  product,  and  please  contact  the  outlet  (the  agency)  at  which 
you purchased the product, or the nearest Koganei service station.

10. Consumables and Optional Parts

Discharge needle unit: DTY-ZKEM (standard type: W hite)

DTY-ZKEMS (air-saving type: Light blue)
DTY-ZKEML (low-dust type: Gray)

Air-saving type replacement filter: DTY-ZKFS (5 filters/set)

AC adapter: DTY-ZKPS

Controller: DTY-ZKCR

Controller unit: DTY-ZKCRU (Unit with solenoid valve)

JUST CONSULT US:
KOGANEI CORPORATION OVERSEAS DEPARTMENT
3-11-28, Midoricho, Koganei-shi, Tokyo, 184-8533, Japan
TEL:+81- 042-383-7271    FAX:+81- 042-383-7276
W ebsite: http://www.koganei.co.jp
The specifications or the appearance of this product are subject to change any 
time without prior notice.

X903918 Rev1.5

Tube-tip

DTRY-ADN-FT01

DTRY-ADN-

00B

Nut B

DTRY-ADN-SW60,-SW90

Nut A

Tube-tip

Lock nut

Main

circuit

Load

Load

Load

 24VDC (red)

 0VDC (black)

H.V OFF (blue)

ALARM NC (white)

ALARM NO (brown)

CHECK NO (yellow)

F.G. (green)

Inside ionizer

Internal circuit

External connection example