1. ION WIPER Installation Precautions
Thank you for purchasing the ION WIPER.
The ION WIPER uses alternating voltage of 2000V, though it is not specified as
high voltage devices in Electric Equipment Standards. Read carefully this
manual and another supplied owner's manual for Ionizer Air Blow
【
DTRY-
ELL01
】
before using, and handle carefully and properly. Always keep this
manual for future reference.
Introduction
WARNING
This product is not explosion-proof. Do not install in locations where flammable gas or solvent is
used such as a painting booth. It could ignite or explode.
Always shut off power before cleaning the discharging needle. Handle the needle with caution
because it has a sharp pointed tip. Wrong handling of it could result in body injury.
This device is designed for use with air. Always supply air before turning the power on.
Never touch and put metals such as wire or tools close to the Ionizer. As a high voltage is applied to
the discharging needle of the Ionizer, it may cause electric shock or breakdown. For installation of
the unit, avoid locations subject to oil or water, high temperature or high humidity, due to this
product's high voltage use. Especially avoid a place subject to high humidity and dew condensation.
2. Overview
The ION WIPER is a unit that removes static charges and dust accumulated on the workpiece
(charged object). The installed Ionizer generates ionized air to neutralize static charges on the object
and at the same time blows the dust off from the surface of the object. The air blown from the front
and upper parts of the both sides forms air curtain, and it prevents the blown-off dust from
contaminating on the surrounding working environment. In addition, the built-in blower fan collects
and vents dust through the exhaust duct on the back side. (Built-in blower fan type: DTY-WCM-□)
3. Configuration and Functions of the Device
The ION WIPER consists of functional components such as the Ionizer (DTRY-ELL01), air curtain,
blower fan, and control circuit for electricity and air that activate those functional components. For
products without equipped blower fan (DTY-WC-□), the following external signal outputs (contacts)
are provided: [VAC START contact] for operation signal of external device to collect dust, [ION
END contact] for a signal to count number of Ionizer operation times, and [ERROR contact] to
indicate abnormal stop of the Ionizer.
-
12
-
WARNING
WARNING
WARNING
Summary of Contents for ION WIPER DTY-WC-L