background image

t

The ION WIPER operates for the time set in 

e

and then stops, and the process for removing

static charges and dust is completed.

When the time for blowing is set to[HOLD]

, ionized air blow is continued while the workpiece

is placed (while the sensor detects the work).

y

To adjust the flow rate of the ionized air blow, use the throttle valve on the back of the Ionizer.

Also,  to  adjust  flow  rate  of  air  curtain,  use  the  throttle  valve  for  air  curtain.    Adjust  them

according to the charged condition of the workpiece and amount of dust as like procedure

e

.

u

When abnormal stop occurs due to faulty removal of static charges

The  ION  WIPER  has  a  function  to  promptly  detect  the  abnormal  condition  of  the  installed

Ionizer and to stop operation of the ION WIPER.  Possible causes for abnormal stop are as

follows:

(a)High voltage output is decreased.

(b)Metal cap is loosened (defective tightening) or contacts with the grounded object.

(c)Close  to  short-circuited  condition  occurs  between  the  discharging  needle  and

grounding electrode, because dirt or dust is accumulated on the electrode.

i

Cancelling abnormal stop

Turn the power off, pull the plug out and check the following:

(a)Metal cap and nozzle do not contact with the grounded object.

(b)Metal cap is securely tightened.

(c)Remove the metal cap, and clean the insulation portion of the main body located near

the discharging needle using isopropyl alcohol.  Then re-install the metal cap.

When the unit stops because the metal cap of the Ionizer contacts with the grounded object

(metal frame, etc.), the abnormal stop can be cancelled by the[RESET]button on the back of

the main body without turning the power off, while in contact between them should be avoided

and remdied..

RESET button

Throttle valve 

for air curtain

Throttle valve 

for Ionizer

16

-

Summary of Contents for ION WIPER DTY-WC-L

Page 1: ...X903454 Ver 2 0 取扱説明書 Ver 2 0 Owner s Manual Ver 2 0 エアカーテンダウンブロー形 DTY WCM S DTY WC S DTY WCM L DTY WC L ION WIPER Air Curtain Down Blow Type ...

Page 2: ...2 1 ION WIPER Installation Precautions 12 2 Overview 12 3 Configuration and Functions of the Device 12 3 1 Major parts Name and Function 13 4 Installation Wiring and Tubing 4 1 Precautions on Installation of the ION WIPER 14 4 2 Exhaust Duct 14 4 3 Power Supply 14 4 4 Wiring for Grounding 14 4 5 Air Tubing 14 4 6 Installation of Expanded Metal 14 5 Operations 15 6 Maintenance and Precautions 18 7 ...

Page 3: ...mperature or high humidity due to this product s high voltage use Especially avoid a place subject to high humidity and dew condensation 2 Overview The ION WIPER is a unit that removes static charges and dust accumulated on the workpiece charged object The installed Ionizer generates ionized air to neutralize static charges on the object and at the same time blows the dust off from the surface of ...

Page 4: ...contact normally open 24VDC 2A MAX 3 1 Major parts Name and Function Internal contact circuit Ionizer compact blow type DTRY ELL01 Throttle valve flow rate adjustment for air curtain Power switch Curtain pipe for air curtain Note Note This does not supply ionized air Shower nozzle outlet for ionized air Photoelectric switch workpiece detecting sensor Photoelectric switch workpiece detecting sensor...

Page 5: ...supply of the unit 4 4 Wiring for Grounding φ 76 3 Note When used with defective grounding of the ION WIPER static charge elimination and dust removal performance will degrade F G M3 4 5 Air Tubing Use urethane or nylon tube with outer diameter of φ8 for air tubing to the ION WIPER The ION WIPER is designed to remove dust accumulated on the workpiece charged object Supply clean air that passes thr...

Page 6: ...n the back of the main body according to the charged condition of the workpiece and amount of dust Selector switch for lonizer operating time ionized air blow time Time to set for ionized air blow 1S to blow for one sec 2S to blow for two sec HOLD to blow continuously r Turn the power on Check to ensure that the indicator for the workpiece detecting sensor turns on then place a work The sensor det...

Page 7: ...re as follows a High voltage output is decreased b Metal cap is loosened defective tightening or contacts with the grounded object c Close to short circuited condition occurs between the discharging needle and grounding electrode because dirt or dust is accumulated on the electrode i Cancelling abnormal stop Turn the power off pull the plug out and check the following a Metal cap and nozzle do not...

Page 8: ...g screws with knobs on the front of the body when picking fallen objects or cleaning inside Note Always supply air during operation of the ION WIPER When the set pressure of the regulator for Ionizer comes lower than the 0 05MPa or the throttle valve is closed to stop the flow of ionized air blow the unit or environment will be adversely affected Note Performance of the ION WIPER to remove dust de...

Page 9: ... the other maintenance and precautions regarding the Ionizer The ION WIPER has PLC in its control section Please consult us when a contact in the circuit comes to the end of its operating life because the PLC requires replacement and repair by the manufacturer Recommended replacement interval is 1 5 to 2 years depending on the frequency of operations Replacement and repair of the PLC is availabie ...

Page 10: ...wer fan Input voltage Consumption current Installed Ionizer Ion balance Note Media Static charge removing performance Note Operating pressure range Set pressure range for Ionizer Connection port Ionizer operating time switched by a selector External output Mass Other mA V MPa kgf cm2 MPa kgf cm2 mm kg ERROR abnormal stop ION END completion of Ionizer operation VAC START external device operation D...

Page 11: ...urtain Throttle valve for Ionizer Air curtain pipe Ion flow IN port φ8 quick fitting 0 2 to 0 7MP a 32 3 64 F G AC cord approx 2 8m with grounding electrode 407 5 200 400 200 100 366 2 46 125 250 200 120 Centrifugal blower for built in blower fan type Power switch Regulator for Ionizer Setting pressure range 0 05 to 0 5MPa Pressure gauge Ion flow Air curtain Transparent cover anti static processed...

Page 12: ...Memo 21 ...

Page 13: ... part or all of the content of this manual is prohibited DTY WCM S DTY WC S DTY WCM L DTY WC L 内容についてのご不明な点や技術的なご質問がございま した ら 下記へお問い合わせ く ださい ク レシー ド事業部 184 8533 東京都小金井市緑町3 11 28 クレシード専用フリーダイヤル 7 0120 55 ゴーゴー 9040 ク レ シ ー ド 改訂履歴 History of Revisions Ver 2 0 英文併記 Ver 2 0 Along with English translation JUST CONSULT US KOGANEI CORPORATION OVERSEAS DEPARTMENT 3 11 28 Midoricho Koganei City Tokyo 184 8...

Page 14: ... 東誠ビル 営業本部 184 8533 東京都小金井市緑町3 11 28 2004年9月10日 初版 5 2005年3月 2版 3 CHAT KOGANEI CORP PRINTED IN JAPAN イオンワイパーに関するお問い合わせ先は ク レシー ド事業部 184 8533 東京都小金井市緑町3 11 28 クレシード専用フリーダイヤル 7 0120 55 ゴーゴー 9040 ク レ シ ー ド URL http www koganei co jp ...

Reviews: