The ION WIPER operates for the time set in
e
and then stops, and the process for removing
static charges and dust is completed.
When the time for blowing is set to[HOLD]
, ionized air blow is continued while the workpiece
is placed (while the sensor detects the work).
y
To adjust the flow rate of the ionized air blow, use the throttle valve on the back of the Ionizer.
Also, to adjust flow rate of air curtain, use the throttle valve for air curtain. Adjust them
according to the charged condition of the workpiece and amount of dust as like procedure
e
.
u
When abnormal stop occurs due to faulty removal of static charges
The ION WIPER has a function to promptly detect the abnormal condition of the installed
Ionizer and to stop operation of the ION WIPER. Possible causes for abnormal stop are as
follows:
(a)High voltage output is decreased.
(b)Metal cap is loosened (defective tightening) or contacts with the grounded object.
(c)Close to short-circuited condition occurs between the discharging needle and
grounding electrode, because dirt or dust is accumulated on the electrode.
i
Cancelling abnormal stop
Turn the power off, pull the plug out and check the following:
(a)Metal cap and nozzle do not contact with the grounded object.
(b)Metal cap is securely tightened.
(c)Remove the metal cap, and clean the insulation portion of the main body located near
the discharging needle using isopropyl alcohol. Then re-install the metal cap.
When the unit stops because the metal cap of the Ionizer contacts with the grounded object
(metal frame, etc.), the abnormal stop can be cancelled by the[RESET]button on the back of
the main body without turning the power off, while in contact between them should be avoided
and remdied..
RESET button
Throttle valve
for air curtain
Throttle valve
for Ionizer
-