6. Maintenance and Precautions
・If water, oil, paint, etc. are adhered on the unit, remove them with waste, cloth or the like.
・Static charge removal level will be reduced, if dirt is adhered on the tip of discharging needle of
the installed Ionizer. In that case, clean the needle with nylon brush (never use wire brush).
Pull out the silicon tube from the Ionizer and rotate the metal cap to remove. Clean the
discharging needle and the surroundings by using waste and brush.
・Refer to the owner's manual of DTRY-ELL01 for the other maintenance and precautions
regarding the Ionizer.
・The ION WIPER has PLC in its control section. Please consult us when a contact in the circuit
comes to the end of its operating life, because the PLC requires replacement and repair by the
manufacturer. Recommended replacement interval is 1.5 to 2 years, depending on the
frequency of operations. (Replacement and repair of the PLC is availabie on a chargeable
basis.)
Warning: Before inspections, cleaning, or maintenance, be sure to switch off power supply.
Before cleaning the discharging needle, handle the needle with caution, because it
has a sharp pointed tip. Wrong handling of it could result in body injury.
Discharging needle
Silicon tube
Metal cap
-