9
DTRY-ELF04 (without back filter): Appearance after discharging needle cleaning
Note: White lines denote the discharging needle shapes when new (at 0 hours of use).
0 h
2500 h
5000 h
10000 h
Discharging Needle Maintenance Period (Rough Guidelines)
Periodic cleaning of the ionizer discharging needle is required.
The photographs below show the accumulation of dust on the tip of the discharging needle used in the steady flow fan type.
Depending on the application conditions, perform the cleaning after 300 to 500 hours of use. When cleaning the discharging needle,
cleaning the louver and the inside of the ionizer body at the same time is recommended.
The photographs below show the shape of the discharging needle after cleaning. The tip of the discharging needle can wear down from
repeated use. While it depends on the application environment and conditions, replacement is recommended after around 10000 hours of use.
When operating the DTRY-ELF04 (without back filter): Appearance of discharging needle
Note: Based on Koganei measurement conditions.
0 h
100 h
300 h
500 h