2
Use an L-shaped bar nozzle.
Use a blow type ionizer with
straight bar nozzle.
Arm
CDs and DVDs, etc.
Use a bender nozzle.
Blow Type Application Examples
●
Removal of static charges and particles on
CDs and DVDs
Use 2-head types with bender nozzles to remove static
charges and particles on CDs and DVDs from both sides.
●
Removal of static charges on workpieces
using a controller
Simultaneously controls the ionizer power supply and air ON/
OFF function.
●
Removal of static charges and dust using
intermittent ion air blowing
Works in combination with the high-cycle solenoid valve,
using high-tact intermittent blowing of ionized air for
removal of static charges and dust .
●
Removal of static charges when taking out or
storing wafers
Avoids electrostatic discharging when taking wafers out of
their cassettes, and prevents the stored wafers from being
attracted to the transfer arm.
●
Removal of static charges on parts when
carried by a parts feeder
Static electricity is generated due to friction of parts while the
parts feeder conveys them, and the parts stick to the feeder’s
surface.
Use the blow type ionizer to prevent parts from becoming
stuck due to static electricity. Also, simultaneous use with a
fan type is effective for the static electricity removal.
●
Removal of static charges on wafers
Use blow type ionizers with shower nozzles that provide
Ionized air flow with a wide angle to remove static charges on
wafers.
●
Removal of static charges when conveying
wafers
Prevents dust from being attracted to the surface of wafers.
Prevents the internal patterns from being damaged.
Use a straight bar nozzle
or shower nozzle.
Dust
Caution:
Depending on the
O N / O F F t i m i n g f o r t h e
ionizer, there could be a
possibility of adverse effects
o n e q u i p m e n t a n d t h e
environment. For details
about application conditions,
consult with Koganei.
Application Examples