6
Technical Information
Blow Type: Flow Rate Characteristics
Static Charge Removing Characteristics When Mini Line Filter (DTRY-LF040) is Mounted
Blow Type: Flow Rate Changes in Relation to Number of Throttle Valve Needle Rotations
0
50
100
150
200
250
0.0
0.1
0.2
0.3
0.4
0.5
Supply air pressure (MPa)
Flow rate
r
/min(ANR)
Without filter
When DTRY-LF040
is mounted
DTRY-ELB01 Flow Rate Characteristics
0
50
100
150
200
250
0.0
0.1
0.2
0.3
0.4
0.5
Supply air pressure (MPa)
Flow rate
r
/min(ANR)
Without filter
When DTRY-LF040
is mounted
DTRY-ELL01 Flow Rate Characteristics
0
1
2
3
4
5
0.0
0.1
0.2
0.3
0.4
0.5
Supply air pressure (MPa)
Static charge removing time (sec)
DTRY-ELB01 Static Charge Removing Characteristics
0
1
2
3
4
5
0.0
0.1
0.2
0.3
0.4
0.5
Supply air pressure (MPa)
Static charge removing time (sec)
When DTRY-LF040
is mounted
Without filter
When DTRY-LF040
is mounted
Without filter
DTRY-ELL01 Static Charge Removing Characteristics
※Nozzle used: Shower nozzle (DTRY-NZR20SW)
※All nozzles have the same flow rate.
※When throttle valve is fully open.
※Nozzle used: Shower nozzle (DTRY-NZL20SW)
※All nozzles have the same flow rate.
※When throttle valve is fully open.
※Nozzle used: Shower nozzle (DTRY-NZR20SW)
※Measurement distance: 50 mm [1.97 in.]
※When throttle valve is fully open.
※Nozzle used: Shower nozzle (DTRY-NZL20SW)
※Measurement distance: 50 mm [1.97 in.]
※When throttle valve is fully open.
0
50
100
150
200
250
1
2
3
4
5
6
7
8
9 10 11 12 13
Number of needle rotations
Flow rate
R
/min (ANR)
0.1 MPa
0.2 MPa
0.3 MPa
0.4 MPa
DTRY-ELB01 Flow Rate Characteristics
0
50
100
150
200
250
1
2
3
4
5
6
7
8
9 10 11 12 13
Number of needle rotations
Flow rate
R
/min (ANR)
0.1 MPa
0.2 MPa
0.3 MPa
0.4 MPa
0.5 MPa
DTRY-ELL01 Flow Rate Characteristics
※Nozzle used: Shower nozzle (DTRY-NZR20SW)
※All nozzles have the same flow rate.
※Nozzle used: Shower nozzle (DTRY-NZL01NS)
※All nozzles have the same flow rate.
Mini Line Filter
DTRY-LF040
Needle
1 MPa
=
145 psi.
1
R
/min
=
0.0353 ft.
3
/min.
1 MPa
=
145 psi.
1
R
/min
=
0.0353 ft.
3
/min.
1 MPa
=
145 psi.