Installation Instructions
WARNING: When using electrical products, basic precautions should always be followed,
including the following:
DANGER: Risk of electric shock.
Connect only to a circuit protected by a Ground-Fault
Circuit-Interrupter (GFCI)*.
Building materials and wiring should be routed away from the blower body and other heat-producing
components of the unit.
Install to permit access for servicing.
A pressure wire connector marked
″
Earth/Ground
″
is provided within the wiring compartment. To reduce
the risk of electric shock, connect this connector to the grounding terminal of your electric service or supply
panel with copper wire equivalent in size to the circuit conductor supplying this equipment.
Pressure wire connectors are provided on the exterior of the junction box, blower or control within this unit
to permit connection of a bonding conductor between this unit and all other exposed metal in the vicinity, as
needed to comply with local requirements.
Grounding is required.
The unit should be installed by a qualified service representative, and grounded.
WARNING: Risk of injury or property damage.
Please read all instructions thoroughly before
beginning installation, including the following requirements.
WARNING: Risk of electric shock.
A qualified electrician should make all electrical connections.
WARNING: Risk of electric shock.
Disconnect power before servicing.
NOTICE: Follow all local plumbing and electrical codes.
In Canada, install this unit in accordance with
the Canadian Electrical Code, Part 1.
*Outside North America, this device may be known as a Residual Current Device (RCD).
Product Information
Electrical Requirements
The installation must have a Class A Ground-Fault Circuit-Interrupter (GFCI) or Residual Current Device
(RCD). The GFCI or RCD protect against line-to-ground shock hazard.
Use a 120 V, 15 A, 60 Hz dedicated
service for the bath.
If the blower supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard.
Product Notices
NOTICE:
Keep the area around the blower clean and free of debris. Ensure that the area around the
blower is free of sawdust, insulation, dirt, and other small loose debris. Such material can block the blower
air ducts and reduce the air flow through the blower.
NOTICE:
This product contains an automatic water purge mode that turns the blower on for two minutes
about 30 minutes after the unit is turned off and drained.
Features
Factory installed components include a blower motor with power supply cord, check valve, air piping, and
user keypad. Other than electrical wiring and plumbing, no assembly is needed.
1198326-2-A