4. Make the Electrical Connections – Canada
WARNING: Risk of electric shock.
Make sure the power has been disconnected before performing
the following procedures.
WARNING: Risk of electric shock.
Connect the blower motor to a properly grounded,
grounding-type Ground-Fault Circuit-Interrupter (GFCI) or Residual Current Device (RCD). This
will provide additional protection against line-to-ground shock hazard.
Locate and secure each supplied junction box a minimum of 1-1/2
″
(38 mm) above the subfloor.
The bath controls and system have been prewired at the factory. A qualified electrician should make
a routine service connection to the junction box.
Connect service to the junction box. The 60 Hz model junction box contains black and white wires
and a ground lug.
A 120 V, 15 A dedicated circuit is required. Provide a Class A GFCI or RCD.
Provide a separate equipment grounding conductor for the inside ground or ground lug. The
conductor
must not
be connected to any current-carrying conductor.
Bond in accordance with national and local codes.
5. Complete the Installation
Test Run the Bath
Fill the bath to a level at least 4
″
(102 mm) above the top of the highest airjet.
Operate the bath for 5 minutes and check all bath piping connections for leaks. Check for leakage
along the front, sides, and back of the bath.
For additional information on bath operation, see the
″
Operating Instructions
″
section.
Finish the Installation
Install water-resistant wallboard and all finished wall, deck, and floor materials.
Apply silicone sealant to seal all areas where the bath and finished wall or deck meet.
Install the faucet trim.
Clean-up After Installation
When cleaning up after installation,
do not use abrasive cleansers,
as they may scratch and dull the
bath surface. Use warm water and a liquid detergent to clean the surface of the bath.
The junction box should be
wired as shown.
Bond in accordance with
national and local codes.
Black
Supply
White
Electrician to
provide suitable
strain relief.
Blower Motor
Electrical Cord
Ground (Green with Yellow Stripe)
Wire Connectors
From Blower Motor
From Blower Motor
L1
Black
N
White
GND
Green with Yellow Stripe
1198326-2-A
8
Kohler Co.