Product Information (cont.)
NOTICE:
Keep the area around the blower motor clean and free of sawdust, insulation, dirt, or other
small loose debris. Such material could plug the blower motor air intake and reduce the air flow through
the blower.
Connections and Service Access
Before installation, ensure proper access to the final connections.
NOTICE: Provide generous, unrestricted service access to the blower.
Before installation, ensure that
there is proper access to the blower motor and final connections. If the blower motor is installed in an
enclosed area, an access panel is required at the blower motor. This panel should be 18
″
(457 mm) wide
and 14
″
(356 mm) high minimum.
Features
Factory assembled components include a blower motor, air harness, control, check valve, butterfly valves,
chromatherapy lights (certain models), electrical harnesses, and an illuminated user keypad. Other than
power wiring and plumbing connections, no assembly is required.
Tools and Materials
Before You Begin
NOTICE: The blower motor and the check valve must be relocated together.
Do not relocate one
without the other.
Blower Information
All material needed for the relocation of the blower motor must be supplied by the installer.
Additional tools and materials you will need to relocate the blower motor:
•
Electrician pliers
•
Assorted screwdrivers
•
Adjustable wrench
•
Drill and bits to install the blower mounting fasteners
•
18 AWG non-metallic sheathed cable, two conductors with ground, with support clips, as required
•
One 4
″
(102 mm) x 2
″
(51 mm) electrical junction box with cover, gasket, and mounting screws
Sealant
Plus:
•
Conventional tools and materials
• Drop cloth
• Fasteners (as necessary)
• Rags
• Saw horses
• Hole saw
Kohler Co.
3
1220597-2-C