background image

INSTALLATION INSTRUCTIONS

TT-1375 4/12a

Original Issue Date:

7/04

Model:

6EKOD/5EFKOD, 9--11EKOZD/7--9EFKOZD, and
8--32EOZD/6.5--27EFOZD

Market:

Marine

Subject:

Fuel/Water Separator Kit GM31994-KP1

Introduction

The marine generator set models shown in Figure 1
require a fuel/water separator located between the fuel
tank and the electric fuel pump.

The fuel/water

separator kit helps to remove water and sediment from
the fuel system. After the kit is installed, verify that all
connections are tight.

6EKOD/5EFKOD

9EKOZD/7EFKOZD

11EKOZD/9EFKOZD

8EOZD/6.5EFOZD

9EOZD/7EFOZD

10EOZD/8.5EFOZD

10EOZD/9EFOZD

13EOZD/11EFOZD

14EOZD/11.5EFOZD

15EOZD/13EFOZD

15.5EOZD/13EFOZD

20EOZD/17EFOZD

20EOZD/17.5EFOZD

23EOZD/20EFOZD

24EOZD/20EFOZD

28EOZD/25EFOZD

32EOZD/28EFOZD

Figure 1

Marine Models Requiring a Fuel/Water
Separator

Fuel/Water Separator Kit

Kit: GM31994-KP1

Qty. Description

Part No.

1

Filter, fuel/water separator

GM41013

Safety Precautions

Observe the following safety precautions while installing
the kit.

Accidental starting.
Can cause severe injury or death.

Disconnect the battery cables before
working

on

the

generator

set.

Remove the negative (--) lead first
when

disconnecting

the

battery.

Reconnect the negative (--) lead last
when reconnecting the battery.

WARNING

Disabling the generator set.

Accidental starting can

cause severe injury or death.

Before working on the

generator set or connected equipment, disable the generator
set as follows: (1) Move the generator set master switch to the
OFF position. (2) Disconnect the power to the battery charger.
(3) Remove the battery cables, negative (--) lead first.
Reconnect the negative (--) lead last when reconnecting the
battery. Follow these precautions to prevent starting of the
generator set by an automatic transfer switch, remote
start/stop switch, or engine start command from a remote
computer.

Installation Procedure

1.

Remove the generator set from service.

1.1

Place the generator set master switch in the OFF
position.

1.2

Disconnect the generator set engine starting
battery(ies), negative (--) lead first.

Reviews: