Complete the Installation (cont.)
Place the handle in the vertical position, as shown.
Rotate the handle clockwise, then reposition the handle at the 2
o’clock position.
For hot and cold water supply installations:
Rotate the handle as
needed to achieve the desired water temperature.
For tempered or filtered water installations:
Turn the handle
counterclockwise to the full cold position.
Secure the cover and handle to the valve with two screws
(provided).
7. Troubleshooting
Symptoms
Probable
Causes
Recommended Action
1.
No water
flow.
A.
There is a
loose
connection.
A.
Remove the valve cover and
check the connections from the
battery to the solenoid and
from the battery holder to the
sensor. Make sure that the
connector arrows are aligned
and that the connection is
secure.
B.
The
supply
stops are
in the
″
OFF
″
position.
B.
Confirm the supply stops are in
the
″
ON
″
position.
C.
The
wires/cables
are
pinched or
damaged.
C.
Remove the cover and inspect
the wires/cables for cuts or
damage. If the wires are cut or
damaged, order a new
solenoid, sensor assembly,
sensor extension cable, or
battery holder. Do not pinch or
damage the wires during
reassembly.
1056542-2-B
10
Kohler Co.