background image

Product Information

Drop-in bath whirlpool

K-1014-HA

shown

Required accessories
Jet trim kit

K-9698

Fixture*:

basin area

top area

weight

Bathing

well

42

(106.7 cm) x

20

(50.8 cm)

51

(129.5 cm) x

24

(61 cm)

110 lbs

(49.8 kg)

water depth

capacity

To

overflow

14

(35.6 cm)

60 gal (227 L)

* Approximate measurements for comparison only.

Pump

Heater

V

Hz

A

1.5 Hp

1.5 kW

240

50/60

11

Included component:
Cut-out template

1022451-7

Required Electrical Service

Dedicated circuit required, protected with a Class A

Ground-Fault Circuit-Interrupter (GFCI) or Earth-Leakage

Circuit-Breaker (ELCB):
Pump/control

220/240 V, 20 A, 50/60 Hz

Installation Notes

NOTE:

Pump protrusion beyond rim.

Install this product according to the installation guide.
Pump must be relocated to custom position at the time of

installation. Provide adequate clearance.
Floor support under whirlpool must provide for a minimum of

1800 lbs. (816.5 kg).
Hot water supply should be 70% of capacity or greater.

Installations will vary.
Fixture conforms to ANSI Standard Z124.1. All dimensions are

nominal.

1" (2.5 cm)

16" 
(40.6 cm)

11" 
(27.9 cm)

9" (22.9 cm)

60" (152.4 cm)

2-3/4" 
(7 cm)

1-1/2" O D

2-1/2" 
(6.4 cm)

20" 
(50.8 cm)

32" (81.3 cm)

Pump Protrudes 
1-1/2" (3.8 cm)

No change in measurements with drain 
shown. (K-7161-AF or K-7161M-AF)

Pump/Control Access 
24" (61 cm) W x 
15" (38.1 cm) H Min

2"
(5.1 cm)

Pump/Control Access 
24" (61 cm) W x 
15" (38.1 cm) H Min

2-1/4" 
(5.7 cm)

1033683-1-B

2

Kohler Co.

Summary of Contents for K-1014

Page 1: ...duct numbers are for Mexico i e K 12345M Los números de productos seguidos de M corresponden a México Ej K 12345M Français page 3 Español página 4 USA 1 800 4 KOHLER Canada 1 800 964 5590 México 001 877 680 1310 kohler com K 1014 1033683 1 B 2005 Kohler Co ...

Page 2: ... A 50 60 Hz Installation Notes NOTE Pump protrusion beyond rim Install this product according to the installation guide Pump must be relocated to custom position at the time of installation Provide adequate clearance Floor support under whirlpool must provide for a minimum of 1800 lbs 816 5 kg Hot water supply should be 70 of capacity or greater Installations will vary Fixture conforms to ANSI Sta...

Page 3: ...contrôle 220 240 V 20 A 50 60 Hz Notes pour l installation REMARQUE Pompe dépassant au delà du rebord Installer ce produit selon le guide d installation La pompe doit être relocalisée à l emplacement sur mesure au moment de l installation Prévoir un dégagement adéquat Le sol sous la baignoire à hydromassage doit pouvoir soutenir une charge minimale de 1800 lbs 816 5 kg L alimentation d eau chaude ...

Page 4: ...ntrol 220 240 V 20 A 50 60 Hz Notas para la instalación NOTA La bomba sobresale del reborde Instale este producto conforme a la guía de instalación La bomba se debe colocar en la posición prevista durante la instalación Deje el espacio libre adecuado El soporte del piso debajo de la bañera de hidromasaje debe poder sostener como mínimo 1800 lbs 816 5 kg El suministro de agua caliente debe llegar a...

Reviews: