Product Information

Applicable product:
Drop-in, 3-side integral flange, left drain

K-1112-GLF

Drop-in, 3-side integral flange, right drain

K-1112-GRF

Fixture*:
Bathing well:
Basin area,

bottom

43

(109.2 cm) x 20-1/2

(52.1 cm)

Basin area, top

53-1/2

(135.9 cm) x 32-1/8

(81.6 cm)

Weight

110 lbs (50 kg)

To overflow:
Water depth

15

(38.1 cm)

Capacity

57 gal (215.9 L)

* Approximate measurements for comparison only.

Drop-in cutout dimensions:
58-1/2

(148.6 cm) x 40-1/2

(102.9 cm)

Blower motor:

Heater

V

Hz

A

300 W

120

60

5

Minimum access panel pump/control:
20

(50.8 cm) W x 15

(38.1 cm) H

required

Required Electrical Service

Dedicated circuit required, protected with a Class A

Ground-Fault Circuit-Interrupter (GFCI):
Pump/control

120 V, 5 A, 60 Hz

Blower motor is supplied with a 24

(61 cm) grounding-type

plug-in cord.

Notes

Install this product according to the installation guide.
Floor support under this product must provide for a minimum of

35 lbs/square foot (171 kg/square meter) loading.
If installing a rim-mount faucet, make sure there is no interference

with the drain overflow and circulating system before drilling any

holes. Consult local and national codes for minimum air gap

requirements if installing a spout on the faucet deck.
The hot water supply should be 70% of the capacity of the bath or

greater. Installations will vary.
This fixture conforms to ANSI Standard Z124.1.2. All dimensions

are nominal.

2-7/8" (7.3 cm)

3" (7.6 cm)

Recommended faucet area

1-1/2" OD

42" (106.7 cm)

21" 
(53.3 cm)

10-13/16"
(27.5 cm)

60" (152.4 cm) 

3-1/8" (7.9 cm)

21" (53.3 cm)

1-1/4" (3.2 cm)

3-1/2" (8.9 cm)

19-1/2"
(49.5 cm)

1-1/4" (3.2 cm)

1" (2.5 cm) from the
Floor to the Bottom
of the Drain

Drop-In Rim

Detail

Tile Flange

Detail

1-1/4"
(3.2 cm)

1-1/2"
(3.8 cm)

No change in measurements if connected
with drain illustrated. (K-11677 or K-11677M)

Blower/Control Access
20" (50.8 cm) W x 
15" (38.1 cm) H Min

1076047-1-D

2

Kohler Co.

Summary of Contents for K-1112-GLF

Page 1: ...umbers are for Mexico i e K 12345M Los números de productos seguidos de M corresponden a México Ej K 12345M Français page 3 Español página 4 USA Canada 1 800 4KOHLER México 001 800 456 4537 kohler com K 1112 GLF K 1112 GRF 1076047 1 D 2010 Kohler Co ...

Page 2: ...to the installation guide Floor support under this product must provide for a minimum of 35 lbs square foot 171 kg square meter loading If installing a rim mount faucet make sure there is no interference with the drain overflow and circulating system before drilling any holes Consult local and national codes for minimum air gap requirements if installing a spout on the faucet deck The hot water su...

Page 3: ...de d installation Le support du sol sous ce produit doit pouvoir soutenir une charge minimale de 35 lbs pied carré 171 kg mètre carré Lors de l installation d un robinet sur le rebord s assurer qu il n y ait pas d interférence avec le trop plein du drain et le système de circulation avant de percer des orifices Consulter les codes nationaux et locaux pour les exigences d espace d air minimum lors ...

Page 4: ...forme a la guía de instalación El soporte del piso debajo de este producto debe poder soportar una carga mínima de 35 lbs pie cuadrado 171 kg metro cuadrado En caso de instalar la grifería en el borde asegúrese de que no interfiera con el rebosadero de desagüe y el sistema de circulación antes de taladrar los orificios Consulte los códigos locales y nacionales para obtener los requisitos mínimos d...

Reviews: