background image

Product Information

Applicable product:
Oval bath whirlpool with heater – drop-in rim

style

K-1146-H

Fixture*:
Bathing well:
Basin area, bottom

46

(116.8 cm) x

19

(48.3 cm)

Basin area, top

55

(139.7 cm) x

29

(73.7 cm)

Weight

61 lbs (27.7 kg)

To overflow:
Water depth

14

(35.6 cm)

Capacity

54 gal (204.4 L)

* Approximate measurements for comparison only.

Pump:

1-speed

V

Hz

A

120

60

7.5

Heater:

kw

V

Hz

A

1.5

120

60

12.5

Included components:
Cut-out template

114859-7

Recommended accessories:
Adjustable trip lever drain – through-the-floor

installation

K-11677

Required Electrical Service (2 required)

Two dedicated circuits required, each protected with Class A

Ground-Fault Circuit-Interrupter (GFCI):
Pump/control

120 V, 15 A, 60 Hz

Heater

120 V, 15 A, 60 Hz

Notes

Install this product according to the installation guide.
Floor support under this product must provide for a minimum of

33 lbs/square foot (158 kg/square meter) loading.
The suction line extends 1

(2.5 cm) beyond the edge of the rim.

The pump base extends 1-1/8

(2.9 cm) beyond the edge of the

rim. Modify the framing as needed.
Two minimum access panels are required as illustrated. These

should be 20

(50.8 cm) wide and 15

(38.1 cm) high.

This fixture conforms to ANSI Standard Z124.1.2. All dimensions

are nominal.

Drop-In 
Rim Detail

1-1/2" 
(3.8 cm)

1-1/2" OD

2 Required 
Pump/Control 
Access Panels

20" 
(50.8 cm)

3-1/8" 
(7.9 cm)

8" (20.3 cm)

2-1/2" 
(6.4 cm)

60" (152.4 cm) 

3" (7.6 cm)

2-7/8" (7.3 cm) 3/8" (1 cm)

17-5/8" 
(44.8 cm)

40" (101.6 cm) 

1" (2.5 cm)

16-1/8" 
(41 cm)

Drain End

1-1/4" (3.2 cm)

9" 
(22.9 cm) 

5" (12.7 cm)

4" (10.2 cm)

1" (2.5 cm)

5/8" (1.6 cm)

10" (25.4 cm)

20" (50.8 cm)

26" (66 cm)

29" (73.7 cm)

29-3/4" (75.6 cm)

28" (71.1 cm)

20" (50.8 cm)

10" (25.4 cm)

8" (20.3 cm)

6" (15.2 cm)

4" (10.2 cm)

1" (2.5 cm)

Cut-Out Detail

Symmetrical About CL

No change in measurements if 
connected with the drain illustrated. 
(K-11677 or K-11677M)

1013782-1-C

2

Kohler Co.

Summary of Contents for K-1146-H

Page 1: ...uct numbers are for Mexico i e K 12345M Los números de productos seguidos de M corresponden a México Ej K 12345M Français page 3 Español página 4 USA 1 800 4 KOHLER Canada 1 800 964 5590 México 001 877 680 1310 kohler com K 1146 H 1013782 1 C 2008 Kohler Co ...

Page 2: ...t under this product must provide for a minimum of 33 lbs square foot 158 kg square meter loading The suction line extends 1 2 5 cm beyond the edge of the rim The pump base extends 1 1 8 2 9 cm beyond the edge of the rim Modify the framing as needed Two minimum access panels are required as illustrated These should be 20 50 8 cm wide and 15 38 1 cm high This fixture conforms to ANSI Standard Z124 ...

Page 3: ...stallation Le support du sol sous ce produit doit pouvoir soutenir une charge minimale de 33 lbs pied carré 158 Kg m2 La ligne d aspiration se prolonge de 1 2 5 cm au delà de l arête du rebord La base de la pompe se prolonge de 1 1 8 2 9 cm au delà de l arête du rebord Modifier le cadrage selon le besoin Deux panneaux d accès minimum sont nécessaires tels qu illustrés Ceux ci doivent être de 20 50...

Page 4: ... soporte del piso debajo de este producto debe poder soportar una carga mínima de 33 lbs pie cuadrado 158 kg metro cuadrado La línea de succión sobresale 1 2 5 cm del filo del borde La base de la bomba sobresale 1 1 8 2 9 cm del filo del borde Modifique la estructura de postes según sea necesario Son necesarios dos paneles de acceso mínimo tal como se ilustra Estos paneles deben tener 20 50 8 cm d...

Reviews: