1.25>132
É
FIELD WIRING COMPARTMENT
PUMP
18”
1-7/8”
8-7/8”
PUMP/CONTROL ACCESS
36”
1-3/4”
21”
15/16”
2-7/8”
3”
1-1/2” I.P.S. THR’D
1-1/2” O.D.
3”
71-3/16”
8
106548-
CA
(9437)
Kohler Co., Kohler WI
4. ROUGHING-IN: K-1215-AC, K-1216-AC
A. ORDERING INFORMATION
Factory installed components include pump and air switch
transmitter.
Information contained in this roughing-in also applies to
K-1216-J1-AA and K-1216-JA-AA.
Whirlpool with wall timer
K-1215-AC
Whirlpool with air actuator (shown)
K-1216-AC
Accessories/hardware:
Drain
K-7161-AF recom-
mended
Vinyl tiling-in bead*
K-1179
optional
*Use K-1179 vinyl bead when wall material contacts any
top surface of bath.
B. REQUIRED ELECTRICAL SERVICE
Dedicated circuits required, protected with Class A
Ground-Fault Circuit-Interrupter (GFCI):
Pump/control
120 V., 15 A, 60 Hz
C. PRODUCT INFORMATION
Fixture:
basin area
top area
weight
Bathing well
52” x 23”
65-1/2” x
26-1/2”
95 lbs.
water depth
capacity
To overflow
15-1/2”
76 gals.
Pump:
hp
V
Hz
A
60 Hz
3/4
120
60
10
D. INSTALLATION NOTES
Refer to installation instructions included with fixture before
beginning installation.
*Some K-1179 tiling-in beads may require trimming of the
bottom edge for proper fit.
ROUGHING-IN NOTES
Fixture dimensions are nominal and conform to toler-
ances in ANSI Standard Z124.1.
No change in measurements if connected with drain
illustrated.
Cut-out
34-1/2” x 70”
Minimum access:
Pump/control box 20” W x 15” H panel required