B.Product Information:

Fixture*:

Basin area

Top area

Weight

Bathing Well

* Approximate measurements for comparison only.

To Overflow

Water depth

Capacity

820x1160mm 1000x1400mm 31kg

350mm

286L

*

820x1160mm

1000x1400mm

31kg

350mm

286

*

.

B.

:

UNIT: mm

Roughing-in:

:

INSTALLATION REQUIREMENTS

INSTALLATION REQUIREMENTS

B. Materials Required

A. Tools Required

B.

A.

·

·

·

·

·

·

·

·

Adjustable pipe
wrench
Rule
Level
Safety shoes
Safety glasses
Square
Pliers
Utility knife

·

·

·

·

·

·

·

Plumbers putty
Wall coverings, as necessary
Silicone sealant
Gypsum ciment (optional)
Construction adhesive
(optional)
Protective covering for
bathtub
Nails

·

·

·

·

·

·

·

·

·
·
·
·
·

·

·

(

)

(

)

(

)

C. Clearance Requirements

Check the rough-in and room dimensions to provide
adequate available space for the bath unit.

C.

2

1036303-T01-B

60

45

450

50

1419

268

52(H=75)

1305

700

1305

490

:

52

Diameter of overflow hole:

52

:

50

Diameter of drain hole:

50

Summary of Contents for K-18778T

Page 1: ...iliarize yourself with the required tools materials and installation sequences Follow the sections that pertain to your particular installation This will help you avoid costly mistakes In addition to...

Page 2: ...uired A Tools Required B A Adjustable pipe wrench Rule Level Safety shoes Safety glasses Square Pliers Utility knife Plumbers putty Wall coverings as necessary Silicone sealant Gypsum ciment optional...

Page 3: ...allation The suggested framing construction is illustrated 1 16 2mm Gap Between Bath Rim and Framing 2 Bath Rim Framing Construction Finished Wall Wall D D Plumbing Preparation Position the plumbing a...

Page 4: ...carefully protect its surface during installation 2a 1305 700 1305 1 4 1 9 2b Whirlpool must be installed level on all top edges 2b IMPORTANT 1036303 T01 B 3 A 3 Fit timber batten supports or check in...

Page 5: ...Silicone Sealant Tiling Bead Brick Rebated Into Wall Ng Silicone Sealant 50 25mm Timber Batten Paste Mortar Tile Packed Out From Wall Paste Mortar Tile Brick Under Flange Tiling Ng Silicone Sealant T...

Page 6: ...ized electrician Please refer to Spa Pump Installation Operation Instructions sheet E 10 RCD PDL681 VMP IMPORTANT Your spa has been factory tested and approved It is the responsability of the installe...

Page 7: ...ers wire brushes or other metal tools One of the powder type detergents may be used on a damp cloth to provide mild abrasive action to the residual plaster A 2 Mequiars 28 A Consumer Responsibilities...

Page 8: ...r after purchase Implied warranties including that of merchantability and fitness for a particular purpose are expressly limited in duration to the duration of this warranty Kohler China disclaims any...

Reviews: